A pulse sensor is built into the slide door RH for jam and foreign object detection and for slide door position detection. The jam and foreign object detection feature of the pulse sensor monitors the operating speed of the slide door while the power slide door is in operation. The slide door position detection feature of the pulse sensor monitors where the slide door is. If the slide door position detection feature outputs a pulse signal that is out of the normal range, the power slide door ECU RH will set DTC B2223.
If DTC B2223 is set, the power slide door system will be turned off. Thus, the slide door can be moved freely and will be switched to manual operation mode (not electrically controlled).
In order to restore the power slide door system to normal operation mode, first solve the problem indicated by DTC B2223 and then manually close the slide door fully (reset operation).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B2223 | A pulse sensor which is built in the slide door motor unit RH is malfunction. | ·
ECU-B fuse ·
Slide door lock release motor RH ·
Slide door motor unit RH ·
Wire harness or connector |
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the N24 ECU connector.
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
|---|---|
| N24-7 (ECUB) - Body ground | 10 to 14 V |
OK
NG
Remove the slide door lock release motor.
Apply the battery voltage to the motor terminals and check the operation of the door lock release motor.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → 1 (SD+)
Battery negative (-) → 2 (SD-) |
Lock release |
26.0 to 30.3 mm (1.02 to 1.19 in.)
OK
NG
Disconnect the K8 release motor connector.
Disconnect the K6 ECU connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| K8-1 (SD+) - K6-9 (RACT) | Below 1 Ω |
| K8-2 (SD-) - Body ground | Below 1 Ω |
| K8-1 (SD+) - Body ground | 10 kΩ or higher |
OK