The inside / outside handles have the ability to control operation of the power slide door. Pulling either handle transmits a request signal to the power slide door ECU RH, which then commands the power slide door control motor and clutch to open / close the power slide door.
Use the Data List to check if the door lock is functioning properly.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnosis Note |
|---|---|---|---|
| Handle SW1 | Handle operation detect switch signal / ON or OFF | ON: Slide door inside / outside handle is pulled
OFF: Slide door inside / outside handle is not pulled |
- |
| Handle SW2 | Handle operation detect switch signal / ON or OFF | ON: Slide door inside / outside handle is pulled
OFF: Slide door inside / outside handle is not pulled |
- |
When the handle switch is operating, the intelligent tester should display as shown in the table.
NG
OK
Remove the slide door handle switch.
Measure the resistance of the slide door handle switch.
| Tester Connection | Door Lock Condition | Specified Condition |
|---|---|---|
| 1 (DS1) - 3 (GND) | Pulled lever | Below 1 Ω |
| 1 (DS1) - 3 (GND) | Not pulled lever | 10 kΩ or higher |
| 2 (DS2) - 3 (GND) | Pulled lever | Below 1 Ω |
| 2 (DS2) - 3 (GND) | Not pulled lever | 10 kΩ or higher |
OK
NG
Disconnect the K9 switch connector.
Disconnect the K6 ECU connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| K9-1 (DS1) - K6-12 (DS1) | 10 kΩ or higher |
| K9-2 (DS2) - K6-7 (DS2) | 10 kΩ or higher |
| K9-3 (GND) - Body ground | Below 1 Ω |
| K9-1 (DS1) - Body ground | Below 1 Ω |
| K9-2 (DS2) - Body ground | Below 1 Ω |
OK
NG