Home › Vehicle Interior › ENGINE HOOD / DOOR › SLIDE DOOR CLOSER SYSTEM › from 2016.05
RM24M0E _58 Vehicle Interior _059569 ENGINE HOOD / DOOR _0292020 SLIDE DOOR CLOSER SYSTEM U

ENGINE HOOD / DOOR  SLIDE DOOR CLOSER SYSTEM  TERMINALS OF ECU  


CHECK DOOR CONTROL RELAY LH (POWER SLIDE DOOR ECU LH) (w/ Power Slide Door)


U185954E02
2.99,0.24 3.292,0.427 0.302,0.188 10 false M22 4,0.24 4.198,0.427 0.198,0.188 10 false L6

a.

Disconnect the L6 and M22 ECU connectors.


b.

Measure the voltage and resistance of each terminal of the wire harness side connectors.

Symbols (Terminal No.) Wiring Color Terminal Description Condition Specified Condition
B (M22-7) - GND (M22-1) R - W-B Power supply Always 10 to 14 V
ECUB (M22-12) - GND (M22-1) R - W-B Power supply Always 10 to 14 V
IG (M22-4) - GND (M22-1) R - W-B Power supply Ignition switch ON 10 to 14 V
GND (M22-1) - Body ground W-B - Body ground Ground Always Below 1 Ω
MSW (M22-8) - GND (M22-1) B - W-B Main switch input Power slide door main switch OFF and fuel lid closed Below 1 Ω
Power slide door main switch ON or fuel lid open 10 kΩ or higher
POL (L6-2) - GND (M22-1) G - W-B PAWL switch input Slide door fully closed to open 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
Partially closed door Below 1 Ω
Slide door fully opened to close 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
FUL (L6-5) - GND (M22-1) BR - W-B Full-latch switch input Slide door open to fully closed Below 1 Ω → 10 kΩ or higher
HAF (L6-12) - GND (M22-1) O - W-B Half-latch switch input Slide door fully open → partially closed Below 1 Ω → 10 kΩ or higher
DS2 (L6-7) - GND (M22-1) LG - W-B Handle switch Handle not operated 10 kΩ or higher
Pull the outside handle or turn the inside handle to close Below 1 Ω
DS1 (L6-10) - GND (M22-1) V - W-B Handle switch Handle not operated 10 kΩ or higher
Pull the outside handle or turn the inside handle to open Below 1 Ω
OS (L6-8) - OSG (L6-4) GR - W Touch switch input Power slide door sensor pushed Below 100 Ω
Power slide door sensor not pushed Between 500 Ω and 1100 Ω


c.

Reconnect the L6 and M22 ECU connectors.


d.

Measure the voltage of the connectors.

Symbols (Terminal No.) Wiring Color Terminal Description Condition Specified Condition
DC- (L6-1) - GND (M22-1) G - W-B Door closer output (Reverse rotation) Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation Below 1 V
Reverse rotation 10 to 14 V
Operation finished Below 1 V
DC+ (L6-9) - GND (M22-1) L - W-B Door closer output (Normal rotation) Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation 10 to 14 V
Reverse rotation Below 1 V
Operation finished Below 1 V
LMT (L6-11) - GND (M22-1) B - W-B Initial position switch input Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation Below 1 V
Reverse rotation Below 1 V
Operation finished 10 to 14 V
RACT (L6-13) - GND (M22-1) R - W-B Latch release output Slide door fully closed and power slide door control switch OFF to ON or power slide door control switch ON (Wireless operation) Below 1 V
Operating slide door close Below 1 V
Partially closed door 10 to 14 V
Slide door fully open Below 1 V



CHECK SLIDE DOOR CLOSER RELAY LH (w/o Power Slide Door)


U188887E02
3.469,0.094 3.719,0.25 0.25,0.156 10 false L12

a.

Disconnect the L12 relay connector.


b.

Measure the voltage and resistance of each terminal of the wire harness side connectors.

Symbols (Terminal No.) Wiring Color Terminal Description Condition Specified Condition
+B (L12-5) - E (L12-8) R - W-B Power supply Always 10 to 14 V
E (L12-8) - Body ground W-B - Body ground Ground Always Below 1 Ω
FULL (L12-3) - GND (L12-7) BR - W-B Full-latch switch input Slide door open to fully closed Below 1 Ω → 10 kΩ or higher
HALF (L12-4) - GND (L12-7) V - W-B Half-latch switch input Slide door fully open → partially closed Below 1 Ω → 10 kΩ or higher
A+ (L12-9) - GND (L12-7) G - W-B Pawl switch input Slide door fully closed to open 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
A+ (L12-9) - GND (L12-7) G - W-B Pawl switch input Partially closed door Below 1 Ω
A+ (L12-9) - GND (L12-7) G - W-B Pawl switch input Slide door fully opened to close 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher


c.

Reconnect the L12 relay connector.


d.

Measure the voltage of the connectors.

Symbols (Terminal No.) Wiring Color Terminal Description Condition Specified Condition
ACT- (L12-1) - GND (L12-7) G - W-B Door closer output (Reverse rotation) Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation Below 1 V
Reverse rotation 10 to 14 V
Operation finished Below 1 V
ACT+ (L12-2) - GND (L12-7) L - W-B Door closer output (Normal rotation) Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation 10 to 14 V
Reverse rotation Below 1 V
Operation finished Below 1 V
LSW (L12-10) - GND (L12-7) W-B - W-B Initial position switch input Slide door open 10 to 14 V
Partially closed door 10 to 14 V
Normal rotation Below 1 V
Pull the outside handle or inside handle 10 to 14 V
Reverse rotation Below 1 V
Operation finished 10 to 14 V



CHECK DOOR CONTROL RELAY RH (POWER SLIDE DOOR ECU RH) (w/ Power Slide Door)


U185955E02
3.917,0.271 4.26,0.458 0.344,0.188 10 false N24 2.99,0.271 3.24,0.458 0.25,0.188 10 false K6

a.

Disconnect the K6 and N24 ECU connectors.


b.

Measure the voltage and resistance of each terminal of the wire harness side connectors.

Symbols (Terminal No.) Wiring Color Terminal Description Condition Specified Condition
B (N24-12) - GND (N24-6) R - W-B Power supply Always 10 to 14 V
ECUB (N24-7) - GND (N24-6) LG - W-B Power supply Always 10 to 14 V
IG (N24-3) - GND (N24-6) R - W-B Power supply Ignition switch ON 10 to 14 V
GND (N24-6) - Body ground W-B - Body ground Ground Always Below 1 Ω
MSW (N24-11) - GND (N24-6) LG - W-B Main switch input Power slide door main switch OFF Below 1 Ω
Power slide door main switch ON 10 kΩ or higher
POL (K6-4) - GND (N24-6) G - W-B PAWL switch input Slide door fully closed to open 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
Partially closed door Below 1 Ω
Slide door fully opened to close 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
FUL (K6-1) - GND (N24-6) BR - W-B Full-latch switch input Slide door open to fully closed Below 1 Ω → 10 kΩ or higher
HAF (K6-10) - GND (N24-6) O - W-B Half-latch switch input Slide door fully open → partially closed Below 1 Ω → 10 kΩ or higher
DS2 (K6-7) - GND (N24-6) LG - W-B Handle switch Handle not operated 10 kΩ or higher
Pull the outside handle or turn the inside handle to close Below 1 Ω
DS1 (K6-12) - GND (N24-6) V - W-B Handle switch Handle not operated 10 kΩ or higher
Pull the outside handle or turn the inside handle to open Below 1 Ω
OS (K6-6) - OSG (K6-2) GR - W Touch switch input Power slide door sensor pushed Below 100 Ω
Power slide door sensor not pushed Between 500 Ω and 1100 Ω


c.

Reconnect the K6 and N24 ECU connectors.


d.

Measure the voltage of the connectors.

Symbols (Terminal No.) Wiring Color Terminal Description Condition Specified Condition
DC- (K6-5) - GND (N24-6) G - W-B Door closer output (Reverse rotation) Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation Below 1 V
Reverse rotation 10 to 14 V
Operation finished Below 1 V
DC+ (K6-13) - GND (N24-6) L - W-B Door closer output (Normal rotation) Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation 10 to 14 V
Reverse rotation Below 1 V
Operation finished Below 1 V
LMT (K6-11) - GND (N24-6) B - W-B Initial position switch input Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation Below 1 V
Reverse rotation Below 1 V
Operation finished 10 to 14 V
RACT (K6-9) - GND (N24-6) R - W-B Latch release output Slide door fully closed and power slide door control switch OFF to ON or power slide door control switch ON (Wireless operation) Below 1 V
Operating slide door close Below 1 V
Partially closed door 10 to 14 V
Slide door fully open Below 1 V



CHECK SLIDE DOOR CLOSER RELAY RH (w/o Power Slide Door)


U188888E02
3.448,0.104 3.729,0.25 0.281,0.146 10 false K12

a.

Disconnect the K12 relay connector.


b.

Measure the voltage and resistance of each terminal of the wire harness side connectors.

Symbols (Terminal No.) Wiring Color Terminal Description Condition Specified Condition
+B (K12-5) - E (K12-8) R - W-B Power supply Always 10 to 14 V
E (K12-8) - Body ground W-B - Body ground Ground Always Below 1 Ω
FULL (K12-3) - GND (K12-7) BR - W-B Full-latch switch input Slide door open to fully closed Below 1 Ω → 10 kΩ or higher
HALF (K12-4) - GND (K12-7) V - W-B Half-latch switch input Slide door fully open → partially closed Below 1 Ω → 10 kΩ or higher
A+ (K12-9) - GND (K12-7) G - W-B Pawl switch input Slide door fully closed to open 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
A+ (K12-9) - GND (K12-7) G - W-B Pawl switch input Partially closed door Below 1 Ω
A+ (K12-9) - GND (K12-7) G - W-B Pawl switch input Slide door fully opened to close 10 kΩ or higher → Below 1 Ω → 10 kΩ or higher


c.

Reconnect the K12 relay connector.


d.

Measure the voltage of the connectors.

Symbols (Terminal No.) Wiring Color Terminal Description Condition Specified Condition
ACT- (K12-1) - GND (K12-7) G - W-B Door closer output (Reverse rotation) Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation Below 1 V
Reverse rotation 10 to 14 V
Operation finished Below 1 V
ACT+ (K12-2) - GND (K12-7) L - W-B Door closer output (Normal rotation) Slide door open Below 1 V
Partially closed door Below 1 V
Normal rotation 10 to 14 V
Reverse rotation Below 1 V
Operation finished Below 1 V
LSW (K12-10) - GND (K12-7) B - W-B Initial position switch input Slide door open 10 to 14 V
Partially closed door 10 to 14 V
Normal rotation Below 1 V
Pull the outside handle or inside handle 10 to 14 V
Reverse rotation Below 1 V
Operation finished 10 to 14 V