This circuit provides power to operate the slide door closer relay.
Remove the PSD LH*1 or PSD RH*2 fuse from the instrument panel junction block.
*1: for LH side
*2: for RH side
Measure the resistance of the fuses.
Below 1 Ω
OK
NG
Disconnect the L12*1 or K12*2 relay connector.
*1: for LH side
*2: for RH side
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
|---|---|
| L12-5 (+B) - Body ground*1 | 10 to 14 V |
| K12-5 (+B) - Body ground*2 | 10 to 14 V |
*1: for LH side
*2: for RH side
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
|---|---|
| L12-8 (E) - Body ground*1 | Below 1 Ω |
| K12-8 (E) - Body ground*2 | Below 1 Ω |
*1: for LH side
*2: for RH side
OK
NG