1.INSPECT FRONT DOOR PANEL SUB-ASSEMBLY LH
Check that the clearance measurements of areas A to E are within the standard range.
| Area | Specified Condition |
|---|---|
| A | 5.2 +-1.5 mm (0.205 +-0.098 in.) |
| B | 9.4 +-1.5 mm (0.370 +-0.098 in.) |
| C | 4.2 +-1.5 mm (0.165 +-0.098 in.) |
| D | 4.7 +-1.5 mm (0.185 +-0.098 in.) |
| E | 15.6 +-2.0 mm (0.614 +-0.079 in.) |