The power back door closer switch only turns on while the switch is being pressed, and turns off when the switch is released.
When the power back door closer switch is on, a power back door close request signal is input to the power back door ECU to close the back door.
Check the Data List for proper functioning of the power back door closer switch.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
|---|---|---|---|
| PBD Close SW | Power back door closer switch signal / ON or OFF | ON: Power back door closer switch ON
OFF: Power back door closer switch OFF |
- |
The display is as specified in the normal condition.
NG
OK
Remove the power back door closer switch.
Measure the resistance of the switch.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Pushed (ON) | Below 1 Ω |
| 3 - 4 | Free (OFF) | 10 kΩ or higher |
OK
NG
Disconnect the S13 switch connector.
Disconnect the M24 ECU connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| S13-3 - M24-4 (DS1) | Below 1 Ω |
| S13-4 - Body ground | Below 1 Ω |
| S13-3 - Body ground | 10 kΩ or higher |
OK
NG