When the engine switch is pushed with the electrical key in the cabin, the main body ECU receives signals to switch the power source mode.
To allow use of the intelligent tester to inspect the push-button start function when the engine switch is off, repeat opening and closing any of the doors. Opening and closing a door establishes communication between the intelligent tester and the main body ECU. (Opening and closing a door can also be simulated by operating a door courtesy light switch.)
Remove the AM2 No. 2 and F/B BATT fuses from the engine room junction block No. 1.
Remove the P/POINT NO. 2, ECU-ACC and RAD No. 2 fuses from the instrument panel junction block RH.
Measure the resistance of the fuse.
When the fuse is shorted, check the system which is supplied the power through the shorted fuse, before replace it.
Below 1 Ω
OK
NG
Check that the connectors are securely connected and the terminals are not deformed or loose.
The connectors are securely connected and the terminals are not deformed or loose.
OK
NG
Disconnect the G57 and G58 main body ECU connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G57-6 (AM1) - Body ground | Always | 11 to 14 V |
| G58-1 (AM2) - Body ground | Always | 11 to 14 V |
OK
NG
Disconnect the G59 main body ECU connector.
Disconnect the 4A instrument panel junction block LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G59-1 (GND1) - Body ground | Always | Below 1 Ω |
| 4A-3 (GND2) - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the 5D and 5A instrument panel junction block RH connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G57-22 (ACCD) - 5D-3 | Always | Below 1 Ω |
| G57-22 (ACCD) or 5D-3 - Body ground | 10 kΩ or higher | |
| 5A-4 - Body ground | Below 1 Ω |
OK
NG
Disconnect the 5M instrument panel junction block RH connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5M-1 - Body ground | Always | 11 to 14 V |
OK
NG
Disconnect the 5K and 5L instrument panel junction block RH connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5D-3 - 5A-4 | Always | Below 1 Ω |
| 5D-3 or 5A-4- Body ground | 10 kΩ or higher | |
| 5M-1 - 5D-26 | When battery voltage is applied to 5D-3 and 5A-4 | Below 1 Ω |
| 5M-1 - 5D-27 | ||
| 5M-1 - 5D-30 | ||
| 5M-1 - 5L-5 | ||
| 5M-1 - Body ground | 10 kΩ or higher | |
| 5M-1 - 5D-26 | When battery voltage is not applied to 5D-3 and 5A-4 | 10 kΩ or higher |
| 5M-1 - 5D-27 | ||
| 5M-1 - 5D-30 | ||
| 5M-1 - 5L-5 |
OK
NG