Home › Engine / Hybrid System › 2AZ-FE CHARGING › CHARGING SYSTEM
RM24M0E _51 Engine / Hybrid System _059576 2AZ-FE CHARGING _0292082 CHARGING SYSTEM L

2AZ-FE CHARGING  CHARGING SYSTEM  PRECAUTION  


IGNITION SWITCH EXPRESSIONS


HINT:

The type of ignition switch used on this model differs according to the specifications of the vehicle. The expressions listed in the table below are used in this section.

Expression Ignition Switch (position) Engine Switch (condition)
Ignition Switch off LOCK Off
Ignition Switch on (IG) ON On (IG)
Ignition Switch on (ACC) ACC On (ACC)
Engine Start START Start



Check that the battery cables are connected to the correct terminals.



Disconnect the battery cables if a quick charge is given to the battery.



Do not perform tests with a high voltage insulation resistance tester.



Never disconnect the battery while the engine is running.



Check that the charging cable is securely connected onto terminal B of the generator and the fuse box.



Do not check whether the generator generates current or not while terminal F is connected to the other terminals.