Home › Engine / Hybrid System › 2GR-FE CHARGING › CHARGING SYSTEM
RM24M0E _51 Engine / Hybrid System _059577 2GR-FE CHARGING _0292085 CHARGING SYSTEM L

2GR-FE CHARGING  CHARGING SYSTEM  PRECAUTION  


IGNITION SWITCH EXPRESSIONS


HINT:

The type of ignition switch used on this model differs according to the specifications of the vehicle. The expressions listed in the table below are used in this section.

Expression Ignition Switch (position) Engine Switch (condition)
Ignition Switch off LOCK Off
Ignition Switch on (IG) ON On (IG)
Ignition Switch on (ACC) ACC On (ACC)
Engine Start START Start



Check that the battery cables are connected to the correct terminals.



Disconnect the battery cables when the battery is given a quick charge.



Do not perform tests with a high voltage insulation resistance tester.



Never disconnect the battery cables while the engine is running.



Check that the charging cable nut is tightened on terminal B of the generator and the engine room R/B.