Home › Engine / Hybrid System › 2GR-FE CHARGING › GENERATOR
RM24M0E _51 Engine / Hybrid System _059577 2GR-FE CHARGING _0292086 GENERATOR G

2GR-FE CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27415 1.INSPECT GENERATOR CLUTCH PULLEY

a.
A128078E01
0.583,0.552 0.899,0.694 0.316,0.142 10 Free 2.53,0.552 2.845,0.694 0.316,0.142 10 Lock

Hold the center of the pulley, and confirm that the outer ring turns counterclockwise and does not turn clockwise.

If the result is not as specified, replace the clutch pulley.


Hide 27310B 2.INSPECT GENERATOR DRIVE END FRAME BEARING

a.
A128080

Check that the bearing is not rough or worn.

OK:

The bearing rotates smoothly.


If the bearing does not rotate smoothly, replace the bearing.


Hide 27370 3.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A128079E01
0.73,0.582 1.202,0.721 0.472,0.139 10 Length

Using vernier calipers, measure the length of the exposed brushes.

Standard exposed length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum exposed length:

4.5 mm (0.177 in.)


If the exposed length is less than the minimum, replace the brush holder assembly.


Hide 27330 4.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A079306

Check that the generator rotor bearing is not rough or worn.

If necessary, replace the generator rotor assembly.


b.
B012264E63
0.333,1.146 0.615,0.115 0.615,0.115 0.438,1.083 false 2.104,0.042 2.802,0.208 0.698,0.167 10 false Ohmmeter 0.667,0.031 1.333,0.198 0.667,0.167 10 false Slip Rings

Check the generator rotor for an open circuit.

i.

Using an ohmmeter, measure the resistance between the slip rings.

Standard resistance:
Condition Specified Condition
Approx. 20°C (68°F) 1.5 to 1.9 Ω


If the result is not as specified, replace the generator rotor assembly.



c.
B012265E56
1.313,0.781 1.573,0.688 false 0.417,1.198 0.844,1.531 false 2.083,0.083 2.802,0.229 0.719,0.146 10 false Ohmmeter 0.896,1.458 1.479,1.635 0.583,0.177 10 false Slip Ring 1.615,0.552 2,0.719 0.385,0.167 10 false Rotor

Check the rotor for a short to ground.

i.

Using an ohmmeter, measure the resistance between the slip ring and rotor.

Standard resistance:
Tester Condition Specified Condition
Slip ring - Rotor 1 MΩ or higher


If the result is not as specified, replace the generator rotor assembly.



d.
A124106E01
0.425,0.354 1.023,0.504 0.598,0.150 10 Diameter

Using vernier calipers, measure the slip ring diameter.

Standard diameter:

14.2 to 14.4 mm (0.559 to 0.567 in.)


Minimum diameter:

14.0 mm (0.551 in.)