Home › Engine / Hybrid System › 2GR-FE CHARGING › BATTERY CURRENT SENSOR
RM24M0E _51 Engine / Hybrid System _059577 2GR-FE CHARGING _0292087 BATTERY CURRENT SENSOR G

2GR-FE CHARGING  BATTERY CURRENT SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 28850 1.CHECK BATTERY CURRENT SENSOR ASSEMBLY

a.

Measure the resistance of the sensor.

A393990E01
2.24,2 2.708,1.76 true 2.24,2.188 2.76,2.365 true 1.375,1.885 1.958,1.99 true 1.396,2.385 1.938,2.167 true 1.01,1.781 1.344,2.01 0.333,0.229 10 true VC5 1.135,2.313 1.552,2.542 0.417,0.229 10 false E2 2.813,2.313 3.229,2.542 0.417,0.229 10 false IB 2.771,1.656 3.188,1.885 0.417,0.229 10 false THB 4.021,0.406 5.823,0.635 1.802,0.229 10 false Resistance kΩ 4.344,0.708 4.76,0.938 0.417,0.229 10 false 6 4.344,0.896 4.76,1.125 0.417,0.229 10 false 5 4.344,1.094 4.76,1.323 0.417,0.229 10 false 4 4.344,1.292 4.76,1.521 0.417,0.229 10 false 3 4.344,1.49 4.76,1.719 0.417,0.229 10 false 2 4.344,1.688 4.76,1.917 0.417,0.229 10 false 1 4.354,1.896 4.771,2.125 0.417,0.229 10 false 0 4.677,2.021 5.094,2.25 0.417,0.229 10 false 10 4.969,2.021 5.385,2.25 0.417,0.229 10 false 20 5.26,2.021 5.677,2.25 0.417,0.229 10 false 30 5.531,2.021 5.948,2.25 0.417,0.229 10 false 40 5.823,2.021 6.24,2.25 0.417,0.229 10 false 50 6.104,2.021 6.521,2.25 0.417,0.229 10 false 60 6.365,2.021 6.781,2.25 0.417,0.229 10 false 70 6.688,1.99 7.104,2.219 0.417,0.229 10 false °C 6.719,2.188 7.146,2.417 0.427,0.229 10 false °F 4.688,2.177 5.104,2.406 0.417,0.229 10 false 50 4.979,2.177 5.396,2.406 0.417,0.229 10 false 68 5.26,2.177 5.677,2.406 0.417,0.229 10 false 86 5.51,2.177 5.927,2.406 0.417,0.229 10 false 104 5.792,2.177 6.208,2.406 0.417,0.229 10 false 122 6.063,2.177 6.479,2.406 0.417,0.229 10 false 144 6.333,2.177 6.75,2.406 0.417,0.229 10 false 158 5.333,2.427 6.417,2.698 1.083,0.271 10 false Temperature

Standard resistance:
Tester Connection Condition Specified Condition
2 (VC5) - 4 (E2) Always 0.1 to 10 kΩ
2 (VC5) - 3 (IB) Always Below 0.5 kΩ
3 (IB) - 4 (E2) Always 0.05 to 10 kΩ
1 (THB) - 4 (E2) 20 to 30°C (68 to 86°F) 1.5 to 2.5 kΩ


HINT:

For Tester Connection 1 (THB) - 4 (E2):

As the temperature increases, the resistance decreases (see graph).


If the result is not as specified, replace the sensor assembly.