Home › Drivetrain › U241E (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSAXLE SYSTEM
RM24M0E _52 Drivetrain _059578 U241E AUTOMATIC TRANSMISSION / TRANSAXLE _0292096 AUTOMATIC TRANSAXLE SYSTEM C

U241E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P0710  Transmission Fluid Temperature Sensor "A" Circuit  P0712  Transmission Fluid Temperature Sensor "A" Circuit Low Input  P0713  Transmission Fluid Temperature Sensor "A" Circuit High Input  


DESCRIPTION

The Automatic Transmission Fluid (ATF) temperature sensor converts the ATF temperature into a resistance value which is input into the ECM.

The ECM applies a voltage to the temperature sensor through ECM terminal THO1.

The sensor resistance changes with the ATF temperature.

One terminal of the sensor is grounded so that the sensor resistance and voltage decrease as the temperature becomes higher.

The ECM calculates the ATF temperature based on the voltage signal.

DTC No. DTC Detection Condition Trouble Area
P0710 ATF temperature sensor resistance changes from (a) to (b) or from (b) to (a) in less than 0.5 sec., and P0712 and P0713 are not detected (1 trip detection logic):
(a) ATF temperature sensor resistance is less than 79 Ω
(b) ATF temperature sensor resistance is more than 156 kΩ
·

Open or short in ATF temperature sensor circuit

·

ATF temperature sensor

·

ECM


P0712 ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1 trip detection logic)
·

Short in ATF temperature sensor circuit

·

ATF temperature sensor

·

ECM


P0713 15 minutes or more after the engine start, ATF temperature sensor resistance is more than 156 kΩ for 0.5 sec. or more (1 trip detection logic)
·

Open in ATF temperature sensor circuit

·

ATF temperature sensor

·

ECM



MONITOR DESCRIPTION

ATF temperature sensor converts ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and the ECM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM will illuminate the MIL and store the DTC.

HINT:
·

*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.

·

*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

·

The ATF temperature can be checked on the intelligent tester display.



WIRING DIAGRAM

C142133E13
6.01,2.76 6.406,2.948 0.396,0.188 10 false ECM 5.51,2.219 5.906,2.406 0.396,0.188 10 false D2 5.51,1.292 5.906,1.479 0.396,0.188 10 false D2 5.833,1.292 6.271,1.479 0.438,0.188 10 false THO1 5.833,2.219 6.313,2.406 0.479,0.188 10 false ETHO 5.521,1.073 5.958,1.26 0.438,0.188 10 false 72 5.521,2.01 6,2.198 0.479,0.188 10 false 95 2.24,1.406 2.635,1.594 0.396,0.188 10 false THO 2.323,2.344 2.646,2.531 0.323,0.188 10 false E2 2.635,1.406 3.031,1.594 0.396,0.188 10 false 1 2.635,2.333 2.958,2.521 0.323,0.188 10 false 6 0.76,2.938 2.344,3.365 1.583,0.427 10 false ATF Temperature Sensor (in ECT Solenoid Valve) 0.771,2.729 1.167,2.885 0.396,0.156 10 false D51

CAUTION / NOTICE / HINT

HINT:

Using the intelligent tester's Data List allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


1.

Warm up the engine.

2.

Turn the ignition switch off.

3.

Connect the intelligent tester to the DLC3.

4.

Turn the ignition switch on (IG) and turn the tester ON.

5.

Enter the following menus: Powertrain / Engine and ECT / Data List.

6.

Follow the instructions on the tester and read the Data List.


ECM:
Item Measurement Item/
Range (Display)
Normal Condition Diagnostic Note
A/T Oil Temperature 1 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 215°C (419°F)
·

After stall test:

Approximately 80°C (176°F)

·

Equal to ambient temperature while engine is cold


If value is -40°C (-40°F) or "150°C (302°F) or more", ATF temperature sensor circuit is open or short circuited

HINT:
·

When DTC P0712 is output and the tester output is 150°C (302°F) or more, there is a short circuit.

·

When DTC P0713 is output and the tester output is -40°C (-40°F), there is an open circuit.

Measure the resistance between terminal THO1 (THO) and the body ground.



Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
150°C (302°F) or more Short circuit

HINT:
·

If a circuit related to the ATF temperature sensor becomes open, P0713 is set in approximately 0.5 seconds.

·

It is not necessary to inspect the circuit when P0711 is set.



PROCEDURE

1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)
a.
C141259E09
2.219,0.969 2.49,0.594 false 2.49,1.635 2.219,1.26 false 2.51,0.479 2.875,0.677 0.365,0.198 10 false THO 2.531,1.583 2.75,1.781 0.219,0.198 10 false E2

Disconnect the D51 wire connector.


b.

Measure the resistance of the transmission wire.

Standard resistance:
Tester Connection Specified Condition
1 (THO) - 6 (E2) 90 Ω to 156 kΩ
1 (THO) - Body ground 1 MΩ or higher
6 (E2) - Body ground 1 MΩ or higher


HINT:

If the resistance is out of the specified range of either of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


Standard resistance:
ATF Temperature Specified Condition
10°C (68°F) 6.4 kΩ
110°C (230°F) 0.2 kΩ




OK

2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)

NG

REPAIR OR REPLACE TRANSMISSION WIRE

2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)
U189334E02
1.219,1.969 0.844,2.625 true 1.219,2.052 1.552,2.625 true 1.625,0.865 2,1.094 0.375,0.229 10 false D2 0.656,2.646 1.063,2.844 0.406,0.198 10 false THO1 1.427,2.646 1.833,2.844 0.406,0.198 10 false ETHO 0.094,0.083 1.479,0.25 1.385,0.167 10 false Wire Harness Side:

a.

Disconnect the D2 ECM connector.


b.

Measure the resistance of the wire harness side connector.

Standard resistance:
Tester Connection Specified Condition
D2-72 (THO1) - D2-95 (ETHO) 90 Ω to 156 kΩ
D2-72 (THO1) - Body ground 1 MΩ or higher
D2-95 (ETHO) - Body ground 1 MΩ or higher




OK

REPLACE ECM

NG

REPAIR OR REPLACE HARNESS AND CONNECTOR