Home › Drivetrain › U241E (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSAXLE SYSTEM
RM24M0E _52 Drivetrain _059578 U241E AUTOMATIC TRANSMISSION / TRANSAXLE _0292096 AUTOMATIC TRANSAXLE SYSTEM C

U241E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2716  Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)  


DESCRIPTION

C366245E01
0.385,1.24 1.438,1.74 1.052,0.5 10 false Line Pressure Control Pressure 0.792,2.604 2.49,2.938 1.698,0.333 10 false Current Flow to Solenoid 4.406,0.604 4.719,0.802 0.313,0.198 10 false ON 4.365,1.198 4.771,1.406 0.406,0.208 10 false OFF 5.271,1.583 5.927,1.844 0.656,0.26 10 false 1 Cycle 5.104,0.458 5.417,0.656 0.313,0.198 10 false A 5.573,1 5.885,1.198 0.313,0.198 10 false B

The throttle pressure that is applied to the primary regulator valve (which modulates the line pressure) causes the solenoid valve SLT, under electronic control, to precisely modulate and generate the line pressure according to the extent that the accelerator pedal is depressed or the output of engine power.

This controls the line pressure and provides smooth shifting characteristics.

Upon receiving a signal of the throttle valve opening angle, the ECM controls the line pressure by sending a predetermined duty ratio* to the solenoid valve, modulating the line pressure and generating throttle pressure.

HINT:

*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B).

Duty Ratio (%) = A / (A + B) x 100


DTC No. DTC Detection Condition Trouble Area
P2716 Either condition (a) or (b) below is detected for 1 sec. or more (1 trip detection logic):
(a) SLT - terminal: 0 V
(b) SLT - terminal: 12 V
·

Open or short in shift solenoid valve SLT circuit

·

Shift solenoid valve SLT

·

ECM



MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store the DTC.

WIRING DIAGRAM

C142133E14
6.021,2.76 6.417,2.948 0.396,0.188 10 false ECM 5.51,2.219 5.906,2.406 0.396,0.188 10 false D2 5.51,1.292 5.906,1.479 0.396,0.188 10 false D2 5.844,1.281 6.281,1.469 0.438,0.188 10 false SLT+ 5.844,2.219 6.323,2.406 0.479,0.188 10 false SLT- 5.521,1.083 5.958,1.271 0.438,0.188 10 false 76 5.521,2.01 6,2.198 0.479,0.188 10 false 75 2.188,1.417 2.583,1.604 0.396,0.188 10 false SLT+ 2.208,2.344 2.531,2.531 0.323,0.188 10 false SLT- 2.646,1.406 3.042,1.594 0.396,0.188 10 false 2 2.646,2.333 2.969,2.521 0.323,0.188 10 false 7 0.823,2.958 2.615,3.344 1.792,0.385 10 false Shift Solenoid Valve SLT (ECT Solenoid Valve) 0.823,2.75 1.219,2.906 0.396,0.156 10 false D51

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
a.
C141259E10
1.958,0.969 2.156,0.51 false 2.167,1.698 1.969,1.25 false 2.031,0.333 2.5,0.531 0.469,0.198 10 false SLT+ 2.073,1.719 2.458,1.917 0.385,0.198 10 false SLT-

Disconnect the D51 wire connector.


b.

Measure the resistance of the transmission wire.

Standard resistance:
Tester Connection Condition Specified Condition
2 (SLT+) - 7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
2 (SLT+) - Body ground 20°C (68°F) 1 MΩ or higher
7 (SLT-) - Body ground 20°C (68°F) 1 MΩ or higher




OK

2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLT
2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)
a.
U189341E02
1.479,1.969 1.26,2.656 true 1.563,1.969 1.781,2.656 true 1.51,0.896 1.885,1.125 0.375,0.229 10 false D2 1.698,2.677 2.104,2.875 0.406,0.198 10 false SLT+ 1.104,2.677 1.51,2.875 0.406,0.198 10 false SLT- 0.135,0.094 1.5,0.26 1.365,0.167 10 false Wire Harness Side:

Disconnect the D2 ECM connector.


b.

Measure the resistance of the wire harness side connector.

Standard resistance:
Tester Connection Condition Specified Condition
D2-76 (SLT+) - D2-75 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
D2-76 (SLT+) - Body ground 20°C (68°F) 1 MΩ or higher
D2-75 (SLT-) - Body ground 20°C (68°F) 1 MΩ or higher




OK

REPLACE ECM

NG

REPAIR OR REPLACE HARNESS AND CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SLT
a.

Remove the shift solenoid valve SLT.


C140848E08
1.021,0.479 1.479,0.938 false 2.24,0.49 1.781,0.948 false 1.031,2.604 1.49,3.073 false 2.24,2.594 1.781,3.063 false 0.906,0.375 1.198,0.583 0.292,0.208 10 false 1 2.281,0.365 2.5,0.563 0.219,0.198 10 false 2 0.917,2.5 1.208,2.708 0.292,0.208 10 false 1 2.281,2.479 2.5,2.677 0.219,0.198 10 false 2 1.208,4.104 1.604,4.354 0.396,0.25 10 false (-) 1.917,4.104 2.281,4.313 0.365,0.208 10 false (+)

b.

Measure the resistance of the solenoid valve.

Standard resistance:

5.0 to 5.6 Ω at 20°C (68°F)



c.

Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.




OK

REPAIR OR REPLACE TRANSMISSION WIRE

NG

REPLACE SHIFT SOLENOID VALVE SLT