The throttle pressure that is applied to the primary regulator valve (which modulates the line pressure) causes the solenoid valve SLT, under electronic control, to precisely modulate and generate the line pressure according to the extent that the accelerator pedal is depressed or the output of engine power.
This controls the line pressure and provides smooth shifting characteristics.
Upon receiving a signal of the throttle valve opening angle, the ECM controls the line pressure by sending a predetermined duty ratio* to the solenoid valve, modulating the line pressure and generating throttle pressure.
*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B).
Duty Ratio (%) = A / (A + B) x 100
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2716 | Either condition (a) or (b) below is detected for 1 sec. or more (1 trip detection logic):
(a) SLT - terminal: 0 V (b) SLT - terminal: 12 V |
·
Open or short in shift solenoid valve SLT circuit ·
Shift solenoid valve SLT ·
ECM |
When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store the DTC.
Disconnect the D51 wire connector.
Measure the resistance of the transmission wire.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (SLT+) - 7 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 2 (SLT+) - Body ground | 20°C (68°F) | 1 MΩ or higher |
| 7 (SLT-) - Body ground | 20°C (68°F) | 1 MΩ or higher |
OK
NG
Disconnect the D2 ECM connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D2-76 (SLT+) - D2-75 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| D2-76 (SLT+) - Body ground | 20°C (68°F) | 1 MΩ or higher |
| D2-75 (SLT-) - Body ground | 20°C (68°F) | 1 MΩ or higher |
OK
NG
Remove the shift solenoid valve SLT.
Measure the resistance of the solenoid valve.
5.0 to 5.6 Ω at 20°C (68°F)
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
Valve moves and makes operating noise.
OK
NG