Home › Drivetrain › U241E (AUTOMATIC TRANSMISSION / TRANSAXLE) › PARK / NEUTRAL POSITION SWITCH
RM24M0E _52 Drivetrain _059578 U241E AUTOMATIC TRANSMISSION / TRANSAXLE _0292098 PARK / NEUTRAL POSITION SWITCH G

U241E AUTOMATIC TRANSMISSION / TRANSAXLE  PARK / NEUTRAL POSITION SWITCH  INSPECTION  


PROCEDURE

Hide 84540 1.INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY

G026080E38
1.75,1.333 1.75,1.688 false 1.323,0.375 1.323,0.875 false 1.406,1.354 1.229,1.698 false 1.219,1.333 0.896,1.719 false 1.75,0.396 1.583,0.885 false 2.083,0.385 1.917,0.875 false 2.25,1.344 2.552,1.698 false 2.083,1.344 2.146,1.688 false 0.969,0.396 1.146,0.885 false 0.896,0.229 1.125,0.438 0.229,0.208 10 false B 1.26,0.198 1.542,0.406 0.281,0.208 10 false 2L 1.656,0.208 1.938,0.417 0.281,0.208 10 false RB 2.042,0.208 2.323,0.417 0.281,0.208 10 false RL 1.167,1.708 1.448,1.917 0.281,0.208 10 false LL 1.677,1.708 1.958,1.917 0.281,0.208 10 false DL 2.583,1.667 2.813,1.875 0.229,0.208 10 false L 0.729,1.677 1.01,1.885 0.281,0.208 10 false NL 2.083,1.719 2.313,1.927 0.229,0.208 10 false PL

a.

Measure the resistance of the switch when the shift lever is moved to each position.

Standard resistance:
Tester Connection Shift Lever Position Specified Condition
6 (PL) - 2 (RB) P Below 1 Ω
6 (PL) - 2 (RB) Not on P 10 kΩ or higher
1 (RL) - 2 (RB) R Below 1 Ω
1 (RL) - 2 (RB) Not on R 10 kΩ or higher
9 (NL) - 2 (RB) N Below 1 Ω
9 (NL) - 2 (RB) Not on N 10 kΩ or higher
7 (DL) - 2 (RB) D Below 1 Ω
7 (DL) - 2 (RB) Not on D 10 kΩ or higher
3 (2L) - 2 (RB) 2 Below 1 Ω
3 (2L) - 2 (RB) Not on 2 10 kΩ or higher
8 (LL) - 2 (RB) L Below 1 Ω
8 (LL) - 2 (RB) Not on L 10 kΩ or higher