The amount of current flow to the solenoid is controlled by the (*) duty ratio of the TCM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.
(*) Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then Duty Ratio = A/(A + B) x 100 (%).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2759 | Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic). | ·
Open or short in shift solenoid valve SLU circuit ·
Shift solenoid valve SLU ·
TCM |
When an open or short in the shift solenoid valve (SLU) circuit is detected, the TCM determines there is a malfunction. The TCM will turn on the MIL and store this DTC.
Remove the TCM from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
|---|---|
| 11 (SLU+) - 5 (SLU-) | 5.0 to 5.6 Ω
(at 20°C (68°F)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
|---|---|
| 11 (SLU+) - Body ground | 10 kΩ or higher |
| 5 (SLU-) - Body ground | 10 kΩ or higher |
NG
OK
Remove the shift solenoid valve SLU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
|---|---|
| 1 - 2 | 5.0 to 5.6 Ω
(at 20°C (68°F)) |
Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
The solenoid makes an operating sound.
OK
NG