1.INSPECT SHIFT SOLENOID VALVE SL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition
20°C (68°F) |
|---|---|
| Solenoid Connector (SL) - Solenoid Body (SL) | 11 to 15 Ω |
If the value is not as specified, replace the shift solenoid valve.
Connect the positive (+) lead to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
The solenoid makes an operating noise.
If the operation cannot be done as specified, replace the shift solenoid valve.
2.INSPECT SHIFT SOLENOID VALVE SLT
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition
20°C (68°F) |
|---|---|
| 1 - 2 | 5.0 to 5.6 Ω |
If the value is not as specified, replace the shift solenoid valve.
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
The solenoid makes an operating noise.
If the operation cannot be done as specified, replace the shift solenoid valve.
3.INSPECT SHIFT SOLENOID VALVE SLU
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition
20°C (68°F) |
|---|---|
| 1 - 2 | 5.0 to 5.6 Ω |
If the value is not as specified, replace the shift solenoid valve.
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
The solenoid makes an operating noise.
If the operation cannot be done as specified, replace the shift solenoid valve.
35220
4.INSPECT SHIFT SOLENOID VALVE SL2
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition
20°C (68°F) |
|---|---|
| 1 - 2 | 5.0 to 5.6 Ω |
If the value is not as specified, replace the shift solenoid valve.
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
The solenoid makes an operating noise.
If the operation cannot be done as specified, replace the shift solenoid valve.
35210
5.INSPECT SHIFT SOLENOID VALVE SL1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition
20°C (68°F) |
|---|---|
| 1 - 2 | 5.0 to 5.6 Ω |
If the value is not as specified, replace the shift solenoid valve.
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
The solenoid makes an operating noise.
If the operation cannot be done as specified, replace the shift solenoid valve.
6.INSPECT SHIFT SOLENOID VALVE SL3
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition
20°C (68°F) |
|---|---|
| 1 - 2 | 5.0 to 5.6 Ω |
If the value is not as specified, replace the shift solenoid valve.
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
The solenoid makes an operating noise.
If the operation cannot be done as specified, replace the shift solenoid valve.
7.INSPECT SHIFT SOLENOID VALVE SL4
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition
20°C (68°F) |
|---|---|
| 1 - 2 | 5.0 to 5.6 Ω |
If the value is not as specified, replace the shift solenoid valve.
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
The solenoid makes an operating noise.
If the operation cannot be done as specified, replace the shift solenoid valve.