Home › Vehicle Interior › AIR CONDITIONING › ROOM TEMPERATURE SENSOR(for Rear Side)
RM24M0E _58 Vehicle Interior _059584 AIR CONDITIONING _0292166 ROOM TEMPERATURE SENSOR(for Rear Side) G

AIR CONDITIONING  ROOM TEMPERATURE SENSOR(for Rear Side)  INSPECTION  


PROCEDURE

Hide 1.INSPECT ROOM TEMPERATURE SENSOR

I035401

a.

b.

Disconnect the connector from the A/C room temperature sensor.


c.

Measure the resistance of the sensor.

I112579E01
3.365,1.917 3.781,1.5 false 2.635,2.302 3.052,1.885 false 1.167,0.573 1.667,0.802 0.5,0.229 10 false 4.0 1.167,0.833 1.667,1.063 0.5,0.229 10 false 3.5 1.167,1.135 1.667,1.365 0.5,0.229 10 false 3.0 1.167,1.406 1.667,1.635 0.5,0.229 10 false 2.5 1.156,1.688 1.656,1.917 0.5,0.229 10 false 2.0 1.167,1.969 1.667,2.198 0.5,0.229 10 false 1.5 1.167,2.25 1.667,2.479 0.5,0.229 10 false 1.0 1.167,2.563 1.667,2.792 0.5,0.229 10 false 0.5 1.167,2.844 1.667,3.073 0.5,0.229 10 false 0.0 1.375,3 1.875,3.229 0.5,0.229 10 false 0 1.354,3.167 1.854,3.396 0.5,0.229 10 false 32 2.833,3 3.333,3.229 0.5,0.229 10 false 20 2.833,3.167 3.333,3.396 0.5,0.229 10 false 68 4.292,3 4.792,3.229 0.5,0.229 10 false 40 4.271,3.167 4.771,3.396 0.5,0.229 10 false 104 3.26,3.344 4.188,3.573 0.927,0.229 10 false Temperature 5.76,3 6.26,3.229 0.5,0.229 10 false 60 5.729,3.167 6.229,3.396 0.5,0.229 10 false 140 6.25,3 6.75,3.229 0.5,0.229 10 false (°C) 6.26,3.167 6.76,3.396 0.5,0.229 10 false (°F) 3.375,1.188 5.448,1.427 2.073,0.24 10 false Maximum permissible value line 1.729,2.323 3.802,2.583 2.073,0.26 10 false Minimum permissible value line 0.042,1.531 1.052,1.771 1.01,0.24 10 false Resistance (kΩ)

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
1 - 2 60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).

If the resistance value is not as specified, replace the sensor.