Home › Vehicle Interior › AIR CONDITIONING › AMBIENT TEMPERATURE SENSOR
RM24M0E _58 Vehicle Interior _059584 AIR CONDITIONING _0292168 AMBIENT TEMPERATURE SENSOR G

AIR CONDITIONING  AMBIENT TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88790B 1.INSPECT AMBIENT TEMPERATURE SENSOR

E358373E01
3.031,1.406 2.417,0.635 false 4.094,0.344 4.5,0.594 0.406,0.25 10 false 4.0 4.313,0.073 5.646,0.344 1.333,0.271 10 false Resistance (kΩ) 4.094,0.542 4.5,0.792 0.406,0.25 10 false 3.5 4.094,0.771 4.5,1.021 0.406,0.25 10 false 3.0 4.094,0.99 4.5,1.24 0.406,0.25 10 false 2.5 4.094,1.208 4.5,1.458 0.406,0.25 10 false 2.0 4.094,1.427 4.5,1.677 0.406,0.25 10 false 1.5 4.094,1.594 4.5,1.844 0.406,0.25 10 false 1.0 4.094,1.833 4.5,2.083 0.406,0.25 10 false 0.5 4.094,2.104 4.5,2.354 0.406,0.25 10 false 0.0 4.365,2.219 4.771,2.469 0.406,0.25 10 false 10 4.375,2.365 4.781,2.615 0.406,0.25 10 false 50 4.771,2.219 5.177,2.469 0.406,0.25 10 false 20 4.771,2.365 5.177,2.615 0.406,0.25 10 false 68 5.24,2.219 5.646,2.469 0.406,0.25 10 false 30 5.25,2.375 5.656,2.625 0.406,0.25 10 false 86 5.688,2.219 6.094,2.469 0.406,0.25 10 false 40 6.146,2.219 6.552,2.469 0.406,0.25 10 false 50 6.604,2.219 6.875,2.458 0.271,0.24 10 false 60 6.563,2.354 6.969,2.604 0.406,0.25 10 false 140 6.104,2.365 6.51,2.615 0.406,0.25 10 false 122 5.135,2.521 6.135,2.74 1,0.219 10 false Temperature 6.844,2.208 7.115,2.417 0.271,0.208 10 false (°C) 5.656,2.375 6.063,2.625 0.406,0.25 10 false 104 1.573,0.51 2.49,0.729 0.917,0.219 10 false Sensor Area 6.854,2.365 7.115,2.635 0.26,0.271 10 false (°F)

a.

Measure the resistance of the sensor.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
1 - 2 60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.


·

When measuring the resistance, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).

If the result is not as specified, replace the ambient temperature sensor.