Home › Vehicle Interior › AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM24M0E _58 Vehicle Interior _059584 AIR CONDITIONING _0292180 AIR CONDITIONING SYSTEM C

AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1411/11  Room Temperature Sensor Circuit  


DESCRIPTION

The room temperature sensor is installed in the instrument panel to detect the room temperature and control the heater and air conditioner AUTO mode. The resistance of the room temperature sensor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier applies a voltage (5 V) to the room temperature sensor and reads voltage changes as changes in the resistance of the room temperature sensor.

DTC No. DTC Detection Condition Trouble Area
B1411/11 Open or short in room temperature sensor circuit
·

Room temperature sensor

·

Wire harness between room temperature sensor and air conditioning amplifier

·

Air conditioning amplifier



WIRING DIAGRAM

E115796E25
1.083,2.167 2.792,2.604 1.708,0.438 10 false G34 5.135,2.167 6.781,2.635 1.646,0.469 10 false G47 2.708,1.052 3.021,1.219 0.313,0.167 10 false + 2.719,1.438 3.031,1.604 0.313,0.167 10 false - 5.375,1.052 5.615,1.198 0.24,0.146 10 false TR 5.375,1.448 5.729,1.594 0.354,0.146 10 false SG-4 2.948,0.938 3.167,1.156 0.219,0.219 10 false 1 2.969,1.344 3.188,1.563 0.219,0.219 10 false 2 5.063,0.917 5.281,1.135 0.219,0.219 10 false 29 5.073,1.323 5.292,1.542 0.219,0.219 10 false 35 5.135,2.333 6.938,2.573 1.802,0.24 10 false Air Conditioning Amplifier 1.094,2.333 2.927,2.583 1.833,0.25 10 false Room Temperature Sensor

PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (ROOM TEMP)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.


c.

Select the item below in the Data List, and read the value displayed on the intelligent tester.

Air conditioning amplifier:
Item Measurement Item / Display (Range) Normal Condition Diagnostic Note
Room Temp Room temperature sensor / Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature is displayed Open circuit: -19°C (-2.2°F)
Short circuit: 70.1°C (158.18°F)


OK:

The display is as specified in the normal condition column.


Result
Result Proceed to
NG A
OK (Checking from PROBLEM SYMPTOMS TABLE) B
OK (Checking from DTC) C



A

2.INSPECT ROOM TEMPERATURE SENSOR

B

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C

REPLACE AIR CONDITIONING AMPLIFIER

2.INSPECT ROOM TEMPERATURE SENSOR
E358379E01
1.76,1.104 2.177,0.688 false 1.667,1.094 1.229,0.688 false 1.031,0.458 1.344,0.656 0.313,0.198 10 false 2 1.042,0.604 1.354,0.802 0.313,0.198 10 false (-) 2.198,0.438 2.51,0.635 0.313,0.198 10 false 1 2.208,0.594 2.521,0.792 0.313,0.198 10 false (+) 4.125,0.063 5.625,0.354 1.5,0.292 10 false Resistance (kΩ) 4,0.313 4.313,0.51 0.313,0.198 10 false 4.0 4,0.51 4.313,0.708 0.313,0.198 10 false 3.5 4,0.729 4.313,0.927 0.313,0.198 10 false 3.0 3.99,0.948 4.302,1.146 0.313,0.198 10 false 2.5 4,1.177 4.313,1.375 0.313,0.198 10 false 2.0 4,1.385 4.313,1.583 0.313,0.198 10 false 1.5 4,1.625 4.313,1.823 0.313,0.198 10 false 1.0 4,1.844 4.313,2.042 0.313,0.198 10 false 0.5 4,2.042 4.313,2.24 0.313,0.198 10 false 0.0 4.229,2.167 4.542,2.365 0.313,0.198 10 false 10 4.198,2.302 4.51,2.5 0.313,0.198 10 false (50) 4.656,2.167 4.969,2.365 0.313,0.198 10 false 20 4.635,2.302 4.948,2.5 0.313,0.198 10 false (68) 5.115,2.167 5.427,2.365 0.313,0.198 10 false 30 5.094,2.302 5.406,2.5 0.313,0.198 10 false (86) 5.563,2.167 5.875,2.365 0.313,0.198 10 false 40 5.5,2.302 5.854,2.51 0.354,0.208 10 false (104) 6.01,2.167 6.323,2.365 0.313,0.198 10 false 50 5.948,2.302 6.344,2.51 0.396,0.208 10 false (122) 6.438,2.167 6.75,2.365 0.313,0.198 10 false 60 6.365,2.302 6.75,2.521 0.385,0.219 10 false (140) 4.885,2.448 6.198,2.667 1.313,0.219 10 false Temperature °C (°F)

a.

Remove the room temperature sensor.


b.

Measure the resistance of the sensor.

Standard resistance:
Tester Connection Condition Specified Condition
1 (+) - 2 (-) 10°C (50°F) 3.00 to 3.73 kΩ
1 (+) - 2 (-) 15°C (59°F) 2.45 to 2.88 kΩ
1 (+) - 2 (-) 20°C (68°F) 1.95 to 2.30 kΩ
1 (+) - 2 (-) 25°C (77°F) 1.60 to 1.80 kΩ
1 (+) - 2 (-) 30°C (86°F) 1.28 to 1.47 kΩ
1 (+) - 2 (-) 35°C (95°F) 1.00 to 1.22 kΩ
1 (+) - 2 (-) 40°C (104°F) 0.80 to 1.00 kΩ
1 (+) - 2 (-) 45°C (113°F) 0.65 to 0.85 kΩ
1 (+) - 2 (-) 50°C (122°F) 0.50 to 0.70 kΩ
1 (+) - 2 (-) 55°C (131°F) 0.44 to 0.60 kΩ
1 (+) - 2 (-) 60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).




OK

3.CHECK WIRE HARNESS (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

NG

REPLACE ROOM TEMPERATURE SENSOR

3.CHECK WIRE HARNESS (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
E358382E01
0.583,0.833 1,1.083 0.417,0.25 1.573,2.417 1.99,2.667 0.417,0.25 1.302,1.698 1.656,1.479 true 2.25,1.75 1.844,1.479 true 1.292,4.146 1.615,3.802 true 2.396,4.208 2.042,3.802 true 0.125,0.073 1.458,0.396 1.333,0.323 10 false Wire Harness Side: 0.99,0.438 2.75,0.813 1.76,0.375 10 false Room Temperature Sensor 0.656,0.875 1.427,1.26 0.771,0.385 10 false G34 1.073,1.646 1.844,2.031 0.771,0.385 10 false (+) 2.292,1.688 2.635,1.917 0.344,0.229 10 false (-) 1.052,2.073 2.833,2.469 1.781,0.396 10 false Air Conditioning Amplifier 1.656,2.448 2.427,2.833 0.771,0.385 10 false G47 1.01,4.167 1.563,4.427 0.552,0.26 10 false SG-4 2.417,4.24 2.813,4.458 0.396,0.219 10 false TR

a.

Disconnect the G34 sensor connector.


b.

Disconnect the G47 amplifier connector.


c.

Measure the resistance of the wire harness side connectors.

Standard resistance:
Tester Connection Specified Condition
G34-1 (+) - G47-29 (TR) Below 1 Ω
G34-2 (-) - G47-35 (SG-4) Below 1 Ω
G34-1 (+) - Body ground 1 MΩ or higher
G34-2 (-) - Body ground 1 MΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR