The ambient temperature sensor is installed in the front part of the condenser to detect the ambient temperature and control the air conditioner. The sensor is connected to the air conditioning amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies a voltage (5 V) to the ambient temperature sensor and reads voltage changes as changes in the resistance of the ambient temperature sensor.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1412/12 | Open or short in ambient temperature sensor circuit | ·
Ambient temperature sensor ·
Wire harness between ambient temperature sensor and combination meter ·
Combination meter ·
Air conditioning amplifier ·
CAN communication line |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Ambi Temp Sens | Ambient temperature sensor /
Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) |
Actual ambient temperature is displayed | Open circuit: -53°C (-63.4°F)
Short circuit: 120°C (248°F) |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (Checking from PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from DTC) | C |
A
B
C
Remove the ambient temperature sensor.
Measure the resistance of the sensor.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 1 - 2 | 15°C (50°F) | 2.45 to 2.88 kΩ |
| 1 - 2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| 1 - 2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| 1 - 2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| 1 - 2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| 1 - 2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| 1 - 2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| 1 - 2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| 1 - 2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| 1 - 2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
OK
NG
Disconnect the B15 sensor connector.
Disconnect the G47 amplifier connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| B15-1 - G47-5 (TAM) | Below 1 Ω |
| B15-2 - G47-13 (SG-2) | Below 1 Ω |
| G47-5 (TAM) - Body ground | 10 kΩ or higher |
| G47-13 (SG-2) - Body ground | 10 kΩ or higher |
OK
NG