The rear air conditioning harness (rear evaporator temperature sensor) is installed on the evaporator in the rear air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and to control the rear air conditioner. It sends signals to the air conditioning amplifier. The signals change in accordance with the resistance of the rear air conditioning harness (rear evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier applies a voltage (5 V) to the rear air conditioning harness (rear evaporator temperature sensor) and reads voltage changes as changes in the resistance of the rear air conditioning harness (rear evaporator temperature sensor). This sensor is used for frost prevention.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1417/17 | Open or short in rear air conditioning harness circuit (rear evaporator temperature sensor) | ·
Rear air conditioning harness (rear evaporator temperature sensor) ·
Wire harness between rear air conditioning harness (rear evaporator temperature sensor) and air conditioning amplifier ·
Air conditioning amplifier |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
|---|---|---|---|
| R-Evap Temp Sen | Rear evaporator temperature sensor /
Min.: -29.7°C (-21.46°F) Max.: 59.6°C (139.28°F) |
Actual rear evaporator temperature is displayed | Open circuit: -29.7°C (-21.46°F)
Short circuit: 59.6°C (139.28°F) |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (Checking from PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from DTC) | C |
A
B
C
Remove the rear air conditioning harness.
Measure the resistance of the harness.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (-) - 8 (+) | -10°C (14°F) | 7.30 to 9.10 kΩ |
| 7 (-) - 8 (+) | -5°C (23°F) | 5.65 to 6.95 kΩ |
| 7 (-) - 8 (+) | 0°C (32°F) | 4.40 to 5.35 kΩ |
| 7 (-) - 8 (+) | 5°C (41°F) | 3.40 to 4.15 kΩ |
| 7 (-) - 8 (+) | 10°C (50°F) | 2.70 to 3.25 kΩ |
| 7 (-) - 8 (+) | 15°C (59°F) | 2.14 to 2.58 kΩ |
| 7 (-) - 8 (+) | 20°C (68°F) | 1.71 to 2.05 kΩ |
| 7 (-) - 8 (+) | 25°C (77°F) | 1.38 to 1.64 kΩ |
| 7 (-) - 8 (+) | 30°C (86°F) | 1.11 to 1.32 kΩ |
Touching the thermistor even slightly may change the resistance value. Be sure to hold the connector of the thermistor.
When measuring, the thermistor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
OK
NG
Disconnect the N17 rear air conditioning harness connector.
Disconnect the G48 amplifier connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| N17-8 (+) - G48-4 (TEC) | Below 1 Ω |
| N17-7 (-) - G48-19 (SGND) | Below 1 Ω |
OK
NG