In this circuit, the compressor receives a refrigerant compression demand signal from the air conditioning amplifier.
Based on this signal, the compressor changes the degree of refrigerant compression.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1451/51 | Open or short in solenoid of externally changeable compressor circuit | ·
Compressor and pulley ·
Wire harness between air conditioning amplifier and compressor and pulley ·
Air conditioning amplifier |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the items below in the Data List, and read the value displayed on the intelligent tester.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Reg Ctrl Currnt | Regulator control current /
Min.: 0 A Max.: 0.997 A |
Value changes between 0 A and 0.997 A in accordance with compressor and magnetic clutch operation | - |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (Checking from PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from DTC) | C |
A
B
C
Disconnect the compressor and pulley connector.
Measure the resistance of the connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 25°C (77°F) | 10.1 to 11.1 Ω |
OK
NG
Disconnect the D40 compressor and pulley connector.
Disconnect the G47 amplifier connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| D40-2 - G47-2 (SOL+) | Below 1 Ω |
| D40-2 - Body Ground | 1 MΩ or higher |
OK
NG
Disconnect the D40 compressor and pulley connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
|---|---|
| D40-1 - Body Ground | Below 1 Ω |
OK
NG