Home › Vehicle Interior › AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2013.04–2016.05
RM24M0E _58 Vehicle Interior _059584 AIR CONDITIONING _0292180 AIR CONDITIONING SYSTEM U

AIR CONDITIONING  AIR CONDITIONING SYSTEM  DATA LIST / ACTIVE TEST  


READ DATA LIST


B135940E01
0.425,2.845 1.557,3.021 1.132,0.177 10 Intelligent Tester 0.6,2.589 0.6,2.832 false 1.48,2.058 1.864,2.214 0.385,0.156 10 DLC3 1.717,2.051 1.841,1.732 false

HINT:

Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators, and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Connect the intelligent tester to the DLC3.


b.

Turn the engine switch on (IG) and turn the intelligent tester ON.


c.

Read the Data List by following the prompts on the tester.

Air conditioning amplifier
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Room Temp Room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature is displayed -
Ambi Temp Sens Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature is displayed -
Solar Sens-D Driver side solar sensor /
Min.: 0, Max.: 255
Driver side solar sensor value increases as brightness increases -
Solar Sens-P Passenger side solar sensor /
Min.: 0, Max.: 255
Passenger side solar sensor value increases as brightness increases -
Coolant Temp Engine coolant temperature sensor /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature is displayed -
Set Temp-D Driver side set temperature /
Min.: 0°C (32°F)
Max.: 30°C (86°F)
Driver side actual set temperature is displayed -
Set Temp-P Passenger side set temperature /
Min.: 0°C (32°F)
Max.: 30°C (86°F)
Passenger side actual set temperature is displayed -
Blower Level Blower motor speed level /
Min.: 0, Max.: 31
Increases in range between 0 and 31 as blower motor speed increases -
Ambi Temp Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)
- -
Air Mix Pulse-D Driver side air mix control servo motor target pulse /
Min.: 0, Max.: 255
Customized value displayed -
Air Mix Pulse-P Passenger side air mix control servo motor target pulse /
Min.: 0, Max.: 255
Customized value displayed -
Air Out Pulse-D Air outlet control servo motor target pulse /
Min.: 0, Max.: 255
Customized value displayed -
A/I Damp Targ Pls Air inlet control servo motor target pulse /
Min.: 0, Max.: 255
Customized value displayed -
Evap Fin Temp Evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature is displayed -
Evap Tag Temp Evaporator target temperature /
Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature is displayed -
Reg Press Sens Regulator pressure sensor /
Min.: 0 kgf/cm2G
Max.: 38.25 kgf/cm2G
Actual regulator pressure is displayed -
Reg Ctrl Currnt Regulator control current /
Min.: 0 A
Max.: 0.997 A
Value changes between 0 A and 0.997 A in accordance with compressor and magnetic clutch operation -
Rear Room Temp Rear room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual rear cabin temperature is displayed -
R-Ambi Temp Sen Rear evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual rear evaporator temperature is displayed -
Set Temp Rear Rear set temperature /
Min.: 0
Max.: 255
Actual rear set temperature is displayed -
Blower Level-R Rear blower motor speed level /
Min.; 0, Max.: 31
Increases in range between 0 and 31 as rear blower motor speed increases -
Air Out Pulse-R Rear side air outlet servo motor target pulse /
Min.: 0, Max.: 255
Customized value displayed -
Air Mix Pulse-R Rear side air mix servo motor target pulse /
Min.: 0, Max.: 255
Customized value displayed -
#Codes Number of trouble codes /
Min.: 0, Max.: 255
Number of DTCs displayed -



PERFORM ACTIVE TEST


HINT:

Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the intelligent tester to the DLC3.


b.

Turn the engine switch on (IG) and turn the intelligent tester ON.


c.

Perform the Active Test by following the prompts on the tester.

Air conditioning amplifier
Tester Display Test Part Control Range Diagnostic Note
Blower Motor Blower motor Min.: 0, Max.: 31 -
A/C Mag Clutch Magnetic clutch relay OFF, ON -
Defogger Rly-R Defogger relay (Rear) OFF, ON -
Electric Heater1 PTC heater 1 OFF, ON -
Electric Heater2 PTC heater 2 OFF, ON -
Electric Heater3 PTC heater 3 OFF, ON -
Air Mix Pulse-D Air mix control servo motor pulse (D side) Min.: 0, Max.: 255 -
Air Mix Pulse-P Air mix control servo motor pulse (P side) Min.: 0, Max.: 255 -
Air Out Pulse-D Air outlet control servo motor pulse (D side) Min.: 0, Max.: 255 -
A/I Damp Targ Pls Air inlet control servo motor target pulse Min.: 0, Max.: 255 -
R Blower Motor Rear blower motor Min.: 0, Max.: 31 -
R Air Mix Pulse Rear air mix servo motor pulse Min.: 0, Max.: 255 -
Ion Generator*1 No. 2 ion generator sub-assembly OFF, ON -

*1: with Ion Generator Assembly