The rear room temperature sensor is installed in the rear panel to detect the rear room temperature and control the heater and air conditioner AUTO mode. The resistance of the rear room temperature sensor changes in accordance with the rear room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies a voltage (5 V) to the rear room temperature sensor and reads voltage changes as changes in the resistance of the rear room temperature sensor.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1419/19 | Open or short in rear room temperature sensor circuit | ·
Rear room temperature sensor ·
Wire harness between rear room temperature sensor and air conditioning amplifier ·
Air conditioning amplifier |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Rear room Temp | Rear room temperature sensor / Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F) |
Actual rear room temperature is displayed | Open circuit: -6.5°C (20.3°F)
Short circuit: 57.25°C (135.05°F) |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
A
B
C
Remove the rear room temperature sensor.
Measure the resistance of the sensor.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (+) - 2 (-) | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 1 (+) - 2 (-) | 15°C (59°F) | 2.45 to 2.88 kΩ |
| 1 (+) - 2 (-) | 20°C (68°F) | 1.95 to 2.30 kΩ |
| 1 (+) - 2 (-) | 25°C (77°F) | 1.60 to 1.80 kΩ |
| 1 (+) - 2 (-) | 30°C (86°F) | 1.28 to 1.47 kΩ |
| 1 (+) - 2 (-) | 35°C (95°F) | 1.00 to 1.22 kΩ |
| 1 (+) - 2 (-) | 40°C (104°F) | 0.80 to 1.00 kΩ |
| 1 (+) - 2 (-) | 45°C (113°F) | 0.65 to 0.85 kΩ |
| 1 (+) - 2 (-) | 50°C (122°F) | 0.50 to 0.70 kΩ |
| 1 (+) - 2 (-) | 55°C (131°F) | 0.44 to 0.60 kΩ |
| 1 (+) - 2 (-) | 60°C (140°F) | 0.36 to 0.50 kΩ |
Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
OK
NG
Disconnect the b1 sensor connector.
Disconnect the G48 amplifier connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| b1-1 - G48-17 (TR) | Below 1 Ω |
| b1-2 - G48-7 (SG-6) | Below 1 Ω |
| b1-1 - Body ground | 1 MΩ or higher |
| b1-2 - Body ground | 1 MΩ or higher |
OK
NG