Home › Vehicle Interior › AIR CONDITIONING › ION GENERATOR SWITCH › 2013.04–2016.05
RM24M0E _58 Vehicle Interior _059584 AIR CONDITIONING _0292183 ION GENERATOR SWITCH G

AIR CONDITIONING  ION GENERATOR SWITCH  INSPECTION  


PROCEDURE

Hide 84740B 1.INSPECT ION GENERATOR SWITCH (AIR PURIFIER SWITCH ASSEMBLY)

a.
E233396E06
0.16,0.102 2.737,0.610 2.577,0.508 10 Component without harness connected: (Ion Generator Switch (Air Purifier Switch Assembly)) 2.544,3.288 2.670,3.450 0.126,0.163 10 E 0.454,3.328 0.767,3.491 0.314,0.163 10 ECU 1.893,3.914 2.388,3.364 2.388,3.364 2.497,3.364 false 1.484,3.914 0.983,3.41 0.983,3.41 0.871,3.41 false 2.074,3.966 2.497,3.665 2.497,3.665 2.673,3.665 false 1.736,3.913 2.254,3.137 2.254,3.137 2.484,3.137 false 2.539,3.05 2.853,3.213 0.314,0.163 10 ILL- 0.618,3.067 0.931,3.230 0.314,0.163 10 ILL+ 2.714,3.58 3.068,3.743 0.353,0.163 10 IND+ 1.33,3.92 0.799,3.692 0.799,3.692 0.627,3.692 false 0.199,3.62 0.557,3.783 0.358,0.163 10 IND- 1.618,3.93 1.229,3.147 1.229,3.147 1,3.147 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
3 (E) - 6 (ECU) Ion generator switch (air purifier switch assembly) on Below 1 Ω
3 (E) - 6 (ECU) Ion generator switch (air purifier switch assembly) off 10 kΩ or higher


If the result is not as specified, replace the ion generator switch (air purifier switch assembly).


b.

Check that the switch illuminates.

i.

Apply battery voltage to the ion generator switch (air purifier switch assembly) and check that the switch illuminates.

OK:
Tester Connection Specified Condition
Battery positive (+) → Terminal 5 (ILL+)
Battery negative (-) → Terminal 4 (ILL-)
Illuminates


If the result is not as specified, replace the ion generator switch (air purifier switch assembly).



c.

Check switch indicator operation.

i.

Apply battery voltage to the ion generator switch (air purifier switch assembly) and check that the switch indicator illuminates.

OK:
Tester Connection Specified Condition
Battery positive (+) → Terminal 2 (IND+)
Battery negative (-) → Terminal 7 (IND-)
Indicator Illuminates