Home › Vehicle Interior › AIR CONDITIONING › FRONT EVAPORATOR TEMPERATURE SENSOR
RM24M0E _58 Vehicle Interior _059584 AIR CONDITIONING _0292187 FRONT EVAPORATOR TEMPERATURE SENSOR G

AIR CONDITIONING  FRONT EVAPORATOR TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625 1.INSPECT EVAPORATOR TEMPERATURE SENSOR

a.
E126546E08
0.865,0.531 0.573,0.531 0.573,0.531 0.396,0.885 false 0.208,1.833 0.563,2.042 0.354,0.208 10 false 10.0 0.292,2.083 0.646,2.292 0.354,0.208 10 false 9.0 0.292,2.292 0.646,2.5 0.354,0.208 10 false 8.0 0.292,2.521 0.646,2.729 0.354,0.208 10 false 7.0 0.292,2.729 0.646,2.938 0.354,0.208 10 false 6.0 0.292,2.948 0.646,3.156 0.354,0.208 10 false 5.0 0.292,3.167 0.646,3.375 0.354,0.208 10 false 4.0 0.292,3.385 0.646,3.594 0.354,0.208 10 false 3.0 0.292,3.604 0.646,3.813 0.354,0.208 10 false 2.0 0.292,3.813 0.813,4.021 0.521,0.208 10 false 1.0 0.292,4.031 0.646,4.24 0.354,0.208 10 false 0.0 0.521,4.135 0.75,4.531 0.229,0.396 10 false -10 14 1.188,4.135 1.375,4.531 0.188,0.396 10 false 0 32 3.229,4.135 3.417,4.448 0.188,0.313 10 false 30 86 2.615,4.135 2.813,4.49 0.198,0.354 10 false 20 68 1.896,4.135 2.094,4.479 0.198,0.344 10 false 10 50 0.938,0.438 1.51,0.583 0.573,0.146 10 false Sensor 0.188,1.552 1.438,1.75 1.25,0.198 10 false Resistance (kΩ) 0.688,3.635 1.594,3.823 0.906,0.188 10 false Temperature 1.75,3.635 2.031,4.042 0.281,0.406 10 false (°C) (°F)

Measure the resistance of the sensor.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 -10°C (14°F) 7.30 to 9.10 kΩ
1 - 2 -5°C (23°F) 5.65 to 6.95 kΩ
1 - 2 0°C (32°F) 4.40 to 5.35 kΩ
1 - 2 5°C (41°F) 3.40 to 4.15 kΩ
1 - 2 10°C (50°F) 2.70 to 3.25 kΩ
1 - 2 15°C (59°F) 2.14 to 2.58 kΩ
1 - 2 20°C (68°F) 1.71 to 2.05 kΩ
1 - 2 25°C (77°F) 1.38 to 1.64 kΩ
1 - 2 30°C (86°F) 1.11 to 1.32 kΩ


NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.


·

When measuring, the sensor temperature must be almost the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph). If the resistance value is not as specified, replace the sensor.