Home › Vehicle Interior › THEFT DETERRENT › THEFT DETERRENT SYSTEM
RM24M0E _58 Vehicle Interior _059585 THEFT DETERRENT _0292193 THEFT DETERRENT SYSTEM D

THEFT DETERRENT  THEFT DETERRENT SYSTEM  SYSTEM DESCRIPTION  


THEFT DETERRENT SYSTEM DESCRIPTION


The theft deterrent system is designed to deter vehicle break-ins and theft. If an attempted break-in or theft is detected, the vehicle horns and security horn will sound and the hazard warning light will flash. The system detects an attempted break-in or theft when any of the following occurs: 1) the vehicle is forcibly entered, 2) the engine hood is forcibly opened, 3) the doors are unlocked without the use of a key, or 4) the cable is disconnected and reconnected from the negative (-) battery terminal.

If the system enters the alarm sounding state, any unlocked doors will automatically lock.

The system has 4 states: disarmed state, arming preparation state, armed and alarm sounding state.


FUNCTION OF MAIN COMPONENT


Function Outline
Security indicator Informs driver of theft deterrent system status
Security horn Sounds when attempted brake-in or theft is detected
Taillight Taillight illuminates if system enters alarm sounding state when system is unset
Hazard warning light Hazard warning light begins flashing when attempted break-in or theft is detected
Vehicle horns Sounds when attempted break-in or theft is detected
Door courtesy light switch Detects door open status (open or closed)
Door lock position switch Detects door lock status (locked or unlocked)
Engine hood courtesy switch Detects engine hood open status (open or closed)
Back door courtesy switch Detects back door open status (open or closed)
Power source control ECU Detects ignition switch (off or on (IG))


SYSTEM FUNCTION


a.

Disarmed state:

·

The alarm function is not operating.

·

The theft deterrent system is not operating.



b.

Arming preparation state:

·

The theft deterrent system is not operating.



c.

Arming state:

·

The theft deterrent system is operating.



d.

Alarm sounding state:

·

The alarm function is operating (30 +-5 seconds).