The combination meter assembly controls the combination meter illumination in accordance with the light control signal from the light control rheostat on the trip switch.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and the tester ON.
Read the Data List according to the prompts displayed on the tester.
| Item | Measurement Item / Range (Display) | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Light Control Switch | Light control rheostat switch signal / ON or OFF | ON: Rheostat switch pushed
OFF: Rheostat switch not pushed |
- |
ON is displayed on the intelligent tester screen when switch is pressed.
NG
OK
Remove the trip switch.
Measure the resistance of the switch.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 4 (TC) - 6 (E) | Rheostat switch pushed | Below 1 Ω |
| 4 (TC) - 6 (E) | Rheostat switch not pushed | 10 kΩ or higher |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 2 (TC) - 10 (E) | Rheostat switch pushed | Below 1 Ω |
| 2 (TC) - 10 (E) | Rheostat switch not pushed | 10 kΩ or higher |
OK
NG
Disconnect the G46 switch connector.
Disconnect the G28 meter connector
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| G46-4 (TC) - G28-35 (TC O) | Below 1 Ω |
| G46-4 (TC) or G28-35 (TC O) - Body ground | 10 kΩ or higher |
| G46-6 (E) - Body ground | Below 1 Ω |
| Tester Connection | Specified Condition |
|---|---|
| G46-2 (TC) - G28-35 (TC O) | Below 1 Ω |
| G46-2 (TC) or G28-35 (TC O) - Body ground | 10 kΩ or higher |
| G46-10 (E) - Body ground | Below 1 Ω |
OK
NG