RM24M0E
_58
Vehicle Interior
_059587
METER / GAUGE / DISPLAY
_0292197
METER / GAUGE SYSTEM
U
METER / GAUGE / DISPLAY METER / GAUGE SYSTEM FAIL-SAFE CHART
Speedometer
| Condition
|
Response
|
Recovery
|
| Speed data is interrupted for 0.24 seconds
|
Gauge needle indicates below 0 km/h
|
Normal data is received
|
Tachometer
| Condition
|
Response
|
Recovery
|
| Tachometer data is interrupted for 0.24 seconds
|
Gauge needle indicates below 0 rpm
|
Normal data is received
|
Water temperature
| Condition
|
Response
|
Recovery
|
| Water temperature data is interrupted for 3.1 seconds
|
Gauge needle indicates below "C"
|
Normal data is received
|
Shift indicator
| Condition
|
Response
|
Recovery
|
| "P" to "D" data is interrupted for 3 seconds
|
All shift indicators go off
|
Normal data is received
|
ODO / TRIP
| Condition
|
Response
|
Recovery
|
| Regular data is interrupted for 0.24 seconds
|
Calculation stops
|
Normal data is received
|