The combination meter assembly controls the fuel receiver gauge in accordance with the resistance of the fuel sender gauge, which varies depending on the amount of fuel remaining in the fuel tank.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the tester ON.
Perform the Active Test according to the prompts displayed on the tester.
| Item | Test Details | Diagnostic Note |
|---|---|---|
| Fuel Meter Operation | EMPTY / 1/2 / FULL | Value selected during Active Test is displayed |
Value selected during Active Test is displayed.
OK
NG
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and the tester ON.
Read the Data List according to the prompts displayed on the tester.
| Item | Measurement Item / Range (Display) | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Fuel Input | Fuel input signal / Min.: 0, Max.: 127.5 | Fuel gauge indicates (F): 58.5
Fuel gauge indicates (1/2): 32.5 Fuel gauge indicates (E): 6.5 |
- |
Meter / gauge value and tester value are the same.
OK
NG
Remove the fuel sender gauge.
Measure the resistance of the gauge.
| Tester Connection | Float Level | Specified Condition |
|---|---|---|
| 1 - 2 | F | 15.0 +-1.5 Ω |
| 1 - 2 | 1/2 | 212.5 +-12.2 Ω |
| 1 - 2 | E | 410.0 +-4.5 Ω |
OK
NG
Disconnect the G28 meter connector.
Disconnect the M17 gauge connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| G28-27 (L) - M17-1 | Below 1 Ω |
| G28-30 (FE) - M17-2 | Below 1 Ω |
| G28-27 (L) or M17-1 - Body ground | 10 kΩ or higher |
| G28-30 (FE) or M17-2 - Body ground | 10 kΩ or higher |
OK
NG