Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › ULTRASONIC SENSOR(for Front Side) › 2013.04–2016.05
RM24M0E _56 Audio / Visual / Telematics _059590 PARK ASSIST / MONITORING _0292207 ULTRASONIC SENSOR(for Front Side) G

PARK ASSIST / MONITORING  ULTRASONIC SENSOR(for Front Side)  INSPECTION  


PROCEDURE

Hide 89341A 1.INSPECT NO. 1 ULTRASONIC SENSOR (for Type A)

a.
E227022E01
1.427,0.478 1.427,1.084 false 1.818,0.478 1.818,1.084 false 2.209,0.478 2.209,1.084 false 1.22,1.2 1.22,1.806 false 1.62,1.2 1.62,1.806 false 2.02,1.2 2.02,1.806 false 1.336,0.272 1.513,0.418 0.177,0.145 10 EI 2.114,0.272 2.291,0.418 0.177,0.145 10 BI 1.708,0.272 1.885,0.418 0.177,0.145 10 SI 1.126,1.836 1.355,1.982 0.229,0.145 10 EO 1.904,1.836 2.146,1.982 0.243,0.145 10 BO 1.497,1.836 1.719,1.982 0.222,0.145 10 SO 0.142,0.105 0.319,0.250 0.177,0.145 10 *a

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (BI) - 5 (EI) Always 10 kΩ or higher
1 (BI) - 2 (BO) Always 10 kΩ or higher
3 (SI) - 4 (SO) Always Below 1 Ω
5 (EI) - 6 (EO) Always Below 1 Ω


Text in Illustration
*a Component without harness connected
(No. 1 Ultrasonic Sensor)

If the result is not as specified, replace the No. 1 ultrasonic sensor.


Hide 89341A 2.INSPECT NO. 1 ULTRASONIC SENSOR (for Type B)

a.
E270573E05
1.958,0.896 2.375,0.479 false 1.958,1.115 2.656,1.115 false 1.958,1.365 2.417,1.74 false 0.948,0.563 1.5,0.896 false 0.823,1.115 1.5,1.115 false 1.021,1.75 1.479,1.354 false 2.729,1.031 3.042,1.229 0.313,0.198 10 false SI 2.479,0.375 2.792,0.573 0.313,0.198 10 false BI 2.51,1.667 2.823,1.865 0.313,0.198 10 false EI 0.552,1.052 0.865,1.25 0.313,0.198 10 false SO 0.615,0.458 0.927,0.656 0.313,0.198 10 false BO 0.771,1.698 1.083,1.896 0.313,0.198 10 false EO 0.115,0.115 0.427,0.313 0.313,0.198 10 false *a

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (BI) - 5 (EI) Always 10 kΩ or higher
1 (BI) - 2 (BO) Always 10 kΩ or higher
3 (SI) - 4 (SO) Always Below 1 Ω
5 (EI) - 6 (EO) Always Below 1 Ω


Text in Illustration
*a Component without harness connected
(No. 1 Ultrasonic Sensor)

If the result is not as specified, replace the No. 1 ultrasonic sensor.