An ultrasonic sensor consists of a sensor portion that transmits and receives ultrasonic waves and a preamplifier that amplifies them. The ultrasonic sensor outputs the ultrasonic waves and sends the received signals to the clearance warning ECU assembly.
Remove the front corner ultrasonic sensor (RH) (See page Audio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR(for Front Side)>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (BI) - 5 (EI) | Always | 10 kΩ or higher |
| 1 (BI) - 2 (BO) | Always | 10 kΩ or higher |
| 3 (SI) - 4 (SO) | Always | Below 1 Ω |
| 5 (EI) - 6 (EO) | Always | Below 1 Ω |
| *a | Component without harness connected
Front Corner Ultrasonic Sensor (RH)) |
OK
NG
(See pageAudio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR(for Front Side)>REMOVAL)
Disconnect the C7 and C8 front corner ultrasonic sensor connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C7-1 (BI) - C8-2 (BO) | Always | Below 1 Ω |
| C7-3 (SI) - C8-4 (SO) | Always | Below 1 Ω |
| C7-5 (EI) - C8-6 (EO) | Always | Below 1 Ω |
| C7-1 (BI) - Body ground | Always | 10 kΩ or higher |
| C7-3 (SI) - Body ground | Always | 10 kΩ or higher |
| C7-5 (EI) - Body ground | Always | 10 kΩ or higher |
OK
NG