Home › Vehicle Interior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM › from 2014.09
RM24M0E _58 Vehicle Interior _059592 WINDOW / GLASS _0292216 POWER WINDOW CONTROL SYSTEM D

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM  INITIALIZATION  


INITIALIZE POWER WINDOW CONTROL SYSTEM (POWER WINDOW REGULATOR MOTOR (ALL DOORS))


CAUTION:

When the power window regulator motor assembly is reinstalled or replaced, the power window control system must be initialized. Functions such as the AUTO UP / DOWN, jam protection and key-off do not operate if the initialization is not performed.


NOTICE:
·

When the power window regulator motor assembly is replaced, DTC B2313 is output. Clear the DTC after the initialization.

·

When performing initialization, do not perform any other procedures.

·

After a door glass or a door glass run has been replaced, the jam protection function may operate unexpectedly when the AUTO UP function is used, due to detection of the different operation learned value of the door glass movement speed. In such cases, the AUTO UP function can be resumed by repeating the following operation at least 5 times:

(a)

Open the power window by fully pushing down the switch.

(b)

Close the power window by fully pulling up the power window switch and holding it at the AUTO UP position.




HINT:
·

By resetting the door glass position of the driver door power window (the pulse sensor), the power window regulator motor is initialized.

·

When the power window regulator motor is not replaced with a new one, the initialization is necessary. Prior to performing the initialization, change the mode to pre-initialization mode by disconnecting the connector of the power window regulator motor while the power window is in operation after the power window regulator motor is reinstalled.



a.

for LHD:

i.

Connect the battery and turn the engine switch on (IG).


ii.

The AUTO light of the power window regulator master switch flashes when the initialization preparation is complete.


iii.

*1: Fully open the power window by pushing down the power window switch, and continue pushing it for at least 1 second after the power window is fully opened.


iv.

*2: Fully close the power window by pulling up the power window switch, and continue pulling it up for at least 1 second after the power window is fully closed.


v.

The power window position is reset (the pulse sensor is initialized), and the power window switch AUTO light changes from flashing to continuous illumination to indicate that the initialization has been successfully completed.

HINT:

If the AUTO light does not change to continuous illumination, even when step *2 is finished, repeat the procedure from step *1.




b.

for RHD:

i.

Connect the battery and turn the engine switch on (IG).


ii.

Fully open the power window by pushing down the power window switch, and continue pushing it for at least 1 second after the power window is fully opened.


iii.

Fully close the power window by pulling up the power window switch, and continue pulling it up for at least 1 second after the power window is fully closed.


iv.

The power window position is reset (the pulse sensor is initialized).