84040
1.INSPECT MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
Check that the LED illuminates.
Apply battery voltage to the master switch and check that the LED illuminates.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 18 (LED)
Battery negative (-) → Terminal 12 (GND) |
LED illuminates |
If the result is not as specified, replace the switch assembly.