84870A
1.INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/ Retract Mirror)
The L position of the left/right adjustment switch: Measure the resistance of the mirror switch.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 9 (VL) - 13 (B)
11 (M+) - 12 (E) |
UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 9 (VL) - 12 (E)
11 (M+) - 13 (B) |
DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 10 (HL) - 13 (B)
11 (M+) - 12 (E) |
LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 10 (HL) - 12 (E)
11 (M+) - 13 (B) |
RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |
If the result is not as specified, replace the switch assembly.
The R position of the left/right adjustment switch: Measure the resistance of the mirror switch.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 8 (VR) - 13 (B)
11 (M+) - 12 (E) |
UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 8 (VR) - 12 (E)
11 (M+) - 13 (B) |
DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 7 (HR) - 13 (B)
11 (M+) - 12 (E) |
LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 7 (HR) - 12 (E)
11 (M+) - 13 (B) |
RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |
If the result is not as specified, replace the switch assembly.
Measure the resistance of the retract switch.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 13 (MF) - 13 (B)
12 (MR) - 12 (E) |
RETURN | Below 1 Ω |
| 13 (MF) - 12 (E)
12 (MR) - 13 (B) |
RETRACT | Below 1 Ω |
If the result is not as specified, replace the switch.
84870A
2.INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/o Retract Mirror)
The L position of the left/right adjustment switch: Measure the resistance of the mirror switch.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 9 (VL) - 13 (B)
11 (M+) - 12 (E) |
UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 9 (VL) - 12 (E)
11 (M+) - 13 (B) |
DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 10 (HL) - 13 (B)
11 (M+) - 12 (E) |
LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 10 (HL) - 12 (E)
11 (M+) - 13 (B) |
RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |
If the result is not as specified, replace the switch assembly.
The R position of the left/right adjustment switch: Measure the resistance of the mirror switch.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 8 (VR) - 13 (B)
11 (M+) - 12 (E) |
UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 8 (VR) - 12 (E)
11 (M+) - 13 (B) |
DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 7 (HR) - 13 (B)
11 (M+) - 12 (E) |
LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 7 (HR) - 12 (E)
11 (M+) - 13 (B) |
RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |