| DTC No. | Detection Item | Trouble Area |
|---|---|---|
| U1002 | Lost Communication with Gateway Module | ·
AFS ECU branch wire and connector ·
Network gateway ECU main wire and connector ·
Network gateway ECU ·
Junction Block RH ·
No. 1 CAN junction connector LH ·
Junction Block LH ·
AFS ECU |
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition | Resistance of Malfunction |
|---|---|---|
| G40-13 (CA2H) - G40-12 (CA2L) | 54 to 69 Ω | Below 54 Ω: Short in line |
| 70 Ω or higher: Open in CAN main bus line | ||
| G40-13 (CA2H) - G15-16 (BAT) | 6 kΩ or higher | Below 6 kΩ: +B short |
| G40-12 (CA2L) - G15-16 (BAT) | 6 kΩ or higher | Below 6 kΩ: +B short |
| G40-13 (CA2H) - G15-4 (CG) | 200 Ω or higher | Below 200 Ω: Ground short |
| G40-12 (CA2L) - G15-4 (CG) | 200 Ω or higher | Below 200 Ω: Ground short |
| Result | Proceed to |
|---|---|
| NG
- Open in CAN main bus line |
A |
| NG
- Short in line - +B short - Ground short |
B |
| OK | C |
A
B
C
Disconnect the G67 No. 1 CAN junction connector LH connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G67-1 (CANH) - G67-2 (CANL) | Ignition switch off | 108 to 132 Ω |
OK
NG
Reconnect the G67 No. 1 CAN junction connector LH connector.
NEXT
Disconnect the LJ junction block LH connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| LJ-1 (CANH) - LJ-5 (CANL) | Ignition switch off | 108 to 132 Ω |
OK
NG
Reconnect the LJ junction block LH connector.
NEXT
Disconnect the LK junction block LH connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| LK-2 (CANH) - LK-3 (CANL) | Ignition switch off | 108 to 132 Ω |
OK
NG
Reconnect the LJ junction block LH connector.
NEXT
Disconnect the G40 network gateway ECU connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G40-13 (CA2H) - G40-12 (CA2L) | Ignition switch off | 108 to 132 Ω |
OK
NG
Disconnect the G67 No. 1 CAN junction connector LH connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| G40-13 (CA2H) - G40-12 (CA2L) | 108 to 132 Ω |
| G40-13 (CA2H) - G15-4 (CG) | 200 Ω or higher |
| G40-12 (CA2L) - G15-4 (CG) | 200 Ω or higher |
| G40-13 (CA2H) - G15-16 (BAT) | 6 kΩ or higher |
| G40-12 (CA2L) - G15-16 (BAT) | 6 kΩ or higher |
NG
OK
Disconnect the LK junction block LH connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
|---|---|
| LK-2 (CANH) - LK-3 (CANL) | 1 MΩ or higher |
| LK-2 (CANH) - G15-4 (CG) | 200 Ω or higher |
| LK-3 (CANL) - G15-4 (CG) | 200 Ω or higher |
| LK-2 (CANH) - G15-16 (BAT) | 6 kΩ or higher |
| LK-3 (CANL) - G15-16 (BAT) | 6 kΩ or higher |
OK
NG
Reconnect the G67 No. 1 CAN junction connector LH connector.
Reconnect the LK junction block LH connector.
NEXT
Disconnect the LJ junction block LH connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| LJ-1 (CANH) - LJ-5 (CANL) | Ignition switch off | 108 to 132 Ω |
| LJ-1 (CANH) - G15-4 (CG) | Ignition switch off | 200 Ω or higher |
| LJ-5 (CANL) - G15-4 (CG) | Ignition switch off | 200 Ω or higher |
| LJ-1 (CANH) - G15-16 (BAT) | Ignition switch off | 6 kΩ or higher |
| LJ-5 (CANL) - G15-16 (BAT) | Ignition switch off | 6 kΩ or higher |
OK
NG
Reconnect the LJ junction block LH connector.
NEXT
Disconnect the G40 network gateway ECU connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G40-13 (CA2H) - G40-12 (CA2L) | Ignition switch off | 108 to 132 Ω |
| G40-13 (CA2H) - G15-4 (CG) | Ignition switch off | 200 Ω or higher |
| G40-12 (CA2L) - G15-4 (CG) | Ignition switch off | 200 Ω or higher |
| G40-13 (CA2H) - G15-16 (BAT) | Ignition switch off | 6 kΩ or higher |
| G40-12 (CA2L) - G15-16 (BAT) | Ignition switch off | 6 kΩ or higher |
OK
NG
Reconnect the G67 No. 1 CAN junction connector LH connector.
NEXT
Disconnect the G83 No. 1 CAN junction connector LH connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G83-1 (CANH) - G83-2 (CANL) | Ignition switch off | 1 MΩ or higher |
| G83-1 (CANH) - G15-4 (CG) | Ignition switch off | 200 Ω or higher |
| G83-2 (CANL) - G15-4 (CG) | Ignition switch off | 200 Ω or higher |
| G83-1 (CANH) - G15-16 (BAT) | Ignition switch off | 6 kΩ or higher |
| G83-2 (CANL) - G15-16 (BAT) | Ignition switch off | 6 kΩ or higher |
OK
NG
Reconnect the G83 No. 1 CAN junction connector LH connector.
NEXT
Disconnect the A28 AFS ECU connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A28-12 (CAN+) - A28-13 (CAN-) | Ignition switch off | 54 to 69 Ω |
| A28-12 (CAN+) - G15-4 (CG) | Ignition switch off | 200 Ω or higher |
| A28-13 (CAN-) - G15-4 (CG) | Ignition switch off | 200 Ω or higher |
| A28-12 (CAN+) - G15-16 (BAT) | Ignition switch off | 6 kΩ or higher |
| A28-13 (CAN-) - G15-16 (BAT) | Ignition switch off | 6 kΩ or higher |
OK
NG
Clear the DTCs.
Recheck for DTCs.
| Result | Proceed to |
|---|---|
| DTC U1002 is output | A |
| Other DTC is output | B |
A
B