2011-2016 FJ Cruiser · Service Manual HEATER & AIR CONDITIONING SYSTEM

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Jul 2007


INSPECT REFRIGERANT VOLUME

I104026E01
  1. Check the sight glass on liquid tube sub-assembly A.
    Test conditions:

    1. Engine running at 1,500 rpm.
    2. Blower speed control switch at HI.
    3. A/C switch ON.
    4. Temperature control lever in MAX. COLD position.
    5. All doors fully open.
    Item
    Symptom
    Amount of Refrigerant
    Corrective Procedures
    1
    Bubbles visible
    Insufficient*
    (1) Check for gas leakage and repair if necessary
    (2) Add refrigerant until bubbles disappear
    2
    No bubbles visible
    Empty, insufficient or too much
    Refer to items 3 and 4
    3
    No temperature difference between compressor inlet and outlet
    Empty or nearly empty
    (1) Check for gas leakage with gas leak detector and repair if necessary
    (2) Add refrigerant until bubbles disappear
    4
    Considerable temperature difference between compressor inlet and outlet
    Correct or too much
    Refer to items 5 and 6
    5
    Immediately after A/C turned OFF, refrigerant becomes clear
    Too much
    (1) Drain or discharge refrigerant
    (2) Bleed air and supply proper amount of purified refrigerant
    6
    Immediately after A/C turned OFF, refrigerant foams and then becomes clear
    Correct
    -

    HINT:
    *: If the ambient temperature is higher than usual but cooling is sufficient, bubbles in the sight glass are permissible.


CHECK REFRIGERANT PRESSURE USING MANIFOLD GAUGE SET

  1. This is a method to identify trouble areas by using a manifold gauge set. Read the manifold gauge pressure under the following conditions.
    Test conditions:

    1. Engine warm.
    2. All doors fully open.
    3. A/C switch ON.
    4. Blower speed control switch at HI.
    5. Engine running at 1,500 rpm.
    6. Air inlet mode damper set at RECIRC.
    7. Temperature control lever in MAX. COLD position.
    8. Air temperature at air inlet 30 to 35°C (86 to 95°F).

    1. E050573
      When the refrigerant volume is correct, the gauge reading indicates as follows:

      Gauge reading:
      Pressure side
      Refrigerant volume
      Low
      0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
      High
      1.37 to 1.57 MPa (14 to 16 kgf/cm2, 199 to 228 psi)

      HINT:
      Pressure varies in accordance with certain conditions (outside air temperature, sunlight and wind).

    2. When there is moisture in the refrigeration system:

      I022117E03

      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      During operation, pressure on low pressure side cycles between normal and vacuum
      Moisture in refrigeration system freezes at expansion valve orifice, causing temporary interruption of cycle
      However, when melted, returns to normal condition
      1. Receiver dryer oversaturated
      2. Moisture in refrigeration system freezes at expansion valve orifice and blocks refrigerant circulation
      1. Replace receiver dryer
      2. Remove moisture from cycle by repeatedly evacuating air
      3. Supply appropriate volume of new refrigerant

    3. When cooling is insufficient:

      I022118E02

      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      1. Pressure low on both low and high pressure sides
      2. Bubbles are seen through sight glass continuously
      3. Cooling performance insufficient
      Gas leakage from refrigeration system
      1. Insufficient refrigerant
      2. Refrigerant leakage
      1. Check for gas leakage using gas leak detector, and repair if necessary
      2. Supply appropriate volume of new refrigerant
      3. If indicated pressure value close to 0 when connected to gauge, create vacuum after inspecting and repairing location of leakage

    4. When the circulation of the refrigerant is poor:

      I022119E02

      Symptoms
      Probable Cause
      Diagnosis
      Corrective Action
      1. Pressure low on both low and high pressure sides
      2. Frost exists on piping from condenser to A/C unit
      Refrigerant flow obstructed by dirt in condenser
      Condenser clogged
      Replace condenser

    5. When the refrigerant does not circulate:

      I022120E15

      Symptoms
      Probable Causes
      Diagnosis
      Corrective Actions
      1. Vacuum indicated on low pressure side, and extremely low pressure indicated on high pressure side
      2. Frost or condensation seen on piping on both sides of condenser or expansion valve
      1. Refrigerant flow obstructed by moisture or dirt in refrigeration system
      2. Refrigerant flow obstructed by gas leakage from expansion valve
      Refrigerant does not circulate
      1. Check expansion valve
      2. Clean expansion valve with compressed air
      3. Replace condenser
      4. Evacuate air and then supply appropriate volume of new refrigerant
      5. For gas leakage from expansion valve, replace expansion valve

    6. When the refrigerant is overcharged or cooling of condenser is insufficient:

      I022121E03

      Symptoms
      Probable Causes
      Diagnosis
      Corrective Actions
      1. Pressure extremely high on both sides
      2. No air bubbles are seen through sight glass even when engine rpm lowers
      1. Excessive refrigerant
      2. Cooling performance of condenser insufficient
      1. Excessive refrigerant
      2. Cooling performance of condenser insufficient
      1. Clean condenser fins
      2. Check condenser fan motor operation by switching A/C ON
      3. If 1 and 2 normal, check amount of refrigerant and supply appropriate volume of refrigerant

    7. When there is air in the refrigeration system:

      I022122E02

      Symptoms
      Probable Causes
      Diagnosis
      Corrective Actions
      1. Pressure extremely high on both low and high pressure sides
      2. Low pressure piping too hot to touch
      3. Bubbles can be seen through sight glass
      Air in refrigeration system
      1. Air in refrigeration system
      2. Insufficient vacuum purging
      1. Check whether compressor oil dirty or insufficient
      2. Evacuate air and supply new refrigerant

    8. When the expansion valve malfunctions:

      I022123E02

      Symptoms
      Probable Causes
      Diagnosis
      Corrective Actions
      1. Pressure extremely high on both low and high pressure sides
      2. Frost or condensation on piping on low pressure side
      Expansion valve malfunction
      1. Excessive refrigerant in low pressure piping
      2. Expansion valve opening too wide
      Replace expansion valve

    9. When the compressor is defective:

      I022124E02

      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      1. Pressure extremely high on both low and high pressure sides
      2. Pressure extremely low on high pressure side
      Internal leakage in compressor
      1. Compression failure of compressor
      2. Leakage from damaged valve or broken sliding parts in compressor
      Repair or replace compressor


INSPECT IDLING SPEED
  1. Warm up the engine.

  1. Inspect idling speed when these conditions are established.

    1. Engine warm.
    2. Blower speed control switch at Hi.
    3. Temperature control lever in MAX. COLD position.

    Standard:
    Condition
    Idling Speed
    Magnetic clutch not engaged
    (Switch A/C OFF)
    650 to 750 rpm
    Magnetic clutch engaged
    (Switch A/C ON)
    750 to 850 rpm

    If the idling speed is not as specified, check the idle control system.