P0115 Engine Coolant Temperature Circuit
Diagnostic trouble codes · Vehicles built from Aug 2009
Also covers:
- P0117 Engine Coolant Temperature Circuit Low Input
- P0118 Engine Coolant Temperature Circuit High Input
Versions by build date: Jul 2007 – Jul 2009 from Aug 2009
DESCRIPTION
A thermistor is built into the Engine Coolant Temperature (ECT) sensor, of which the resistance value varies according to the ECT.The structure of the sensor and its connection to the ECM are the same as those of the Intake Air Temperature (IAT) sensor.
- HINT:
- When any of DTCs P0115, P0117 and P0118 are set, the ECM enters fail-safe mode. During fail-safe mode, the ECT is estimated to be 80°C (176°F) by the ECM. Fail-safe mode continues until a pass condition is detected.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0115 |
Open or short in Engine Coolant Temperature (ECT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0117 |
Short in Engine Coolant Temperature (ECT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0118 |
Open in Engine Coolant Temperature (ECT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
- HINT:
- When any of these DTCs are set, check the ECT by entering the following menus: Powertrain / Engine and ECT / Data List / All Data / Coolant Temp.
Temperature Displayed
Malfunction
-40°C (-40°F)
Open circuit
140°C (284°F) or higher
Short circuit
MONITOR DESCRIPTION
The Engine Coolant Temperature (ECT) sensor is used to monitor the ECT. The ECT sensor has a thermistor with a resistance that varies according to the temperature of the engine coolant. When the coolant temperature is low, the resistance in the thermistor increases. When the temperature is high, the resistance drops.These variations in resistance are reflected in the voltage output from the sensor. The ECM monitors the sensor voltage and uses this value to calculate the ECT. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a fault in the ECT sensor and sets a DTC.
Example:
If the sensor voltage output is more than 4.91 V for 0.5 seconds or more, the ECM determines that there is an open in the ECT sensor circuit, and sets DTC P0118. Conversely, if the voltage output is less than 0.14 V for 0.5 seconds or more, the ECM determines that there is a short in the sensor circuit, and sets DTC P0117.
If the malfunction is not repaired successfully, a DTC is set 0.5 seconds after the engine is next started.
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data, from the time the malfunction occurred.
| 1. READ VALUE USING INTELLIGENT TESTER (ENGINE COOLANT TEMPERATURE) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / Coolant Temp.
Read the value displayed on the tester.
- Standard:
- Between 80°C and 97°C (176°F and 207°F) with warm engine.
Result Result
Proceed to
-40°C (-40°F)
A
140°C (284°F) or higher
B
Between 80°C and 97°C (176°F and 207°F)
C
- HINT:
- If there is an open circuit, the tester indicates -40°C (-40°F).
- If there is a short circuit, the tester indicates 140°C (284°F) or higher.
- If there is an open circuit, the tester indicates -40°C (-40°F).
|
|
||||
|
|
||||
| A | |
| 2. READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN WIRE HARNESS) |
![]() ![]() |
Disconnect the Engine Coolant Temperature (ECT) sensor connector.
Connect terminals 1 and 2 of the ECT sensor connector on the wire harness side.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / Coolant Temp.
Read the value displayed on the tester.
- Standard:
- 140°C (284°F) or higher
Text in Illustration *1
ECT Sensor
*2
ECM
*3
Front view of wire harness connector
(to ECT Sensor)
|
|
||||
| OK | ||
| ||
| 3. READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN ECM) |
![]() ![]() |
Disconnect the ECT sensor connector.
Connect terminals THW and ETHW of the ECM connector.
- HINT:
- Before checking, do visual and contact pressure checks on the ECM connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / Coolant Temp.
Read the value displayed on the tester.
- Standard:
- 140°C (284°F) or higher
Text in Illustration *1
ECT Sensor
*2
ECM
*3
Rear view of wire harness connector
(to ECM)
|
|
||||
| OK | ||
| ||
| 4. READ VALUE USING INTELLIGENT TESTER (CHECK FOR SHORT IN WIRE HARNESS) |
![]() ![]() |
Disconnect the ECT sensor connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / Coolant Temp.
Read the value displayed on the tester.
- Standard:
- -40°C (-40°F)
Text in Illustration *1
ECT Sensor
*2
ECM
|
|
||||
| OK | ||
| ||
| 5. READ VALUE USING INTELLIGENT TESTER (CHECK FOR SHORT IN ECM) |
Disconnect the ECM connector.

Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / Coolant Temp.
Read the value displayed on the tester.
- Standard:
- -40°C (-40°F)
Text in Illustration *1
ECT Sensor
*2
ECM
*3
Rear view of wire harness connector
(to ECM)
|
|
||||
| OK | ||
| ||



