Home › ENGINE › 1GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0013    Camshaft Position "B" Actuator Circuit / Open (Bank 1)

DTC    P0023    Camshaft Position "B" Actuator Circuit / Open (Bank 2)

for Preparation Click here


DESCRIPTION

The VVT (variable valve timing) system adjusts the exhaust valve timing to improve the driveability. The engine oil pressure turns the camshaft timing exhaust gear assembly to adjust the valve timing. The OCV is a solenoid valve and switches the engine oil line. The valve moves when the ECM applies 12 V to the solenoid. The ECM changes the energizing time to the solenoid (duty-cycle) in accordance with the camshaft position, crankshaft position, throttle position, etc.

A209140E44


DTC No.
DTC Detection Condition
Trouble Area
P0013
Open or short in OCV (for exhaust side of bank 1) circuit (1 trip detection logic).
  1. Open or short in OCV (for exhaust side of bank 1) circuit
  2. Camshaft timing oil control valve assembly (for exhaust side of bank 1)
  3. ECM
P0023
Open or short in OCV (for exhaust side of bank 2) circuit (1 trip detection logic).
  1. Open or short in OCV (for exhaust side of bank 2) circuit
  2. Camshaft timing oil control valve assembly (for exhaust side of bank 2)
  3. ECM

MONITOR DESCRIPTION

This DTC is designed to detect opens or shorts in the camshaft oil control valve (OCV) circuit. If the OCV duty-cycle is excessively high or low while the engine is running, the ECM will illuminate the MIL and store the DTC.

MONITOR STRATEGY


Related DTCs
P0013: Exhaust VVT oil control valve range check (Bank 1)
P0023: Exhaust VVT oil control valve range check (Bank 2)
Required Sensors/Components (Main)
Exhaust VVT oil control valve
Required Sensors/Components (Related)
-
Frequency of operation
Continuous
Duration
1 second
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
Monitor runs whenever following DTCs not present
None
All of following conditions met
-
Starter
OFF
Ignition switch
ON
Time after ignition switch off to ON
0.5 seconds or more

Case 1 
One of following conditions met
-
A. All of following conditions met
-
Battery voltage
11 or more, and less than 13 V
Target duty cycle
Less than 70%
B. All of following conditions met
-
Battery voltage
13 V or more
Target duty cycle
Less than 80%

Case 2 
Current cut status
Not cut

TYPICAL MALFUNCTION THRESHOLDS


Case 1 
Output duty cycle
100% or more

Case 2 
Output duty cycle
3% or less

COMPONENT OPERATING RANGE


Output duty cycle
More than 3%, and less than 100%

CONFIRMATION DRIVING PATTERN

  1. Connect the Techstream to the DLC3.
  2. Turn the ignition switch to ON and turn the Techstream on.
  3. Clear DTCs (even if no DTCs are stored, perform the clear DTC operation).
  4. Turn the ignition switch off and wait for at least 30 seconds.
  5. Turn the ignition switch to ON and turn the Techstream on.
  6. Wait 5 seconds.
  7. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
  8. Read DTCs.

    HINT:
    1. If a DTC is output, the system is malfunctioning.
    2. If a DTC is not output, perform the following procedure.

  9. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  10. Input the DTC: P0013 or P0023.
  11. Check the DTC judgment result.

    Techstream Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU's memory limit

    HINT:
    1. If the judgment result shows NORMAL, the system is normal.
    2. If the judgment result shows ABNORMAL, the system has a malfunction.

  12. If the judgment result is INCOMPLETE or N/A and no DTC is output, perform a universal trip and check for permanent DTCs (Click here).

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.


WIRING DIAGRAM


A226832E06


INSPECTION PROCEDURE

HINT:
  1. Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
  2. If DTC P0013 is output, check the bank 1 VVT system for exhaust side circuit.
  3. Bank 1 refers to the bank that includes the No. 1 cylinder*.
    *: The No. 1 cylinder is the cylinder which is farthest from the transmission.
  4. If DTC P0023 is output, check the bank 2 VVT system for exhaust side circuit.
  5. Bank 2 refers to the bank that does not include the No. 1 cylinder.

1.CHECK WHETHER DTC OUTPUT RECURS (DTC P0013 OR P0023)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Clear the DTCs (Click here).

  1. Start the engine and warm it up.

  1. Allow the engine to idle 1 minute or more.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Read DTCs.
    Result 
    Result
    Proceed to
    P0013 or P0023 is output
    A
    No output
    B



B
CHECK FOR INTERMITTENT PROBLEMS (Click here)
A


2.INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (FOR EXHAUST SIDE)


    A160397E23
  1. Disconnect the camshaft timing oil control valve assembly (for exhaust side).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    6.9 to 7.9 Ω

    Text in Illustration 
    *1
    Component without harness connected
    (Camshaft Timing Oil Control Valve Assembly (for Exhaust Side))



NG
REPLACE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (FOR EXHAUST SIDE) (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (OCV FOR EXHAUST SIDE - ECM)
  1. Disconnect the camshaft timing oil control valve assembly (for exhaust side).

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    B55-1 - B48-21 (OE1+)
    Always
    Below 1 Ω
    B55-2 - B48-22 (OE1-)
    Always
    Below 1 Ω
    B56-1 - B47-21 (OE2+)
    Always
    Below 1 Ω
    B56-2 - B47-22 (OE2-)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    B55-1 or B48-21 (OE1+) - Body ground
    Always
    10 kΩ or higher
    B55-2 or B48-22 (OE1-) - Body ground
    Always
    10 kΩ or higher
    B56-1 or B47-21 (OE2+) - Body ground
    Always
    10 kΩ or higher
    B56-2 or B47-22 (OE2-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)