Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Entire Combination Meter does not Operate

for Preparation Click here


DESCRIPTION

This circuit provides power to the combination meter assembly.

WIRING DIAGRAM


E126859E03


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
E214881E02
  1. Disconnect the E13 combination meter assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E13-21 (ES) - Body ground
    Always
    Below 1 Ω

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    E13-2 (IG+) - Body ground
    Ignition switch ON
    11 to 14 V
    E13-1 (B) - Body ground
    Always
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Combination Meter Assembly)

  1. Reconnect the combination meter connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)