DTC P2714 Pressure Control Solenoid "D" Performance (Shift Solenoid Valve SLT) |

| DTC No. | DTC Detection Conditions | Trouble Area |
| P2714 | ECM detects malfunctions on SLT (ON side) according to the revolution difference between the turbine and the output shaft, and also by monitoring the oil pressure (2 trip detection logic). |
|
| Related DTCs | P2714 : Shift solenoid valve SLT/ON malfunction |
| Required sensors/Components (Main) | Shift solenoid valve SLT |
| Required sensors/Components (Related) | Valve body, ATF temperature sensor, Speed sensor (NT), Speed sensor (SP2) |
| Frequency of operation | Continuous |
| Duration | Immediate |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | P0717 (Turbine speed sensor (NT) circuit) P0722 (Output speed sensor (SP2) circuit) P0712, P0713, P2742, P2743 (Transmission fluid temperature sensor "A" circuit) P0973, P0974 (Shift solenoid "A" (S1) circuit) P0976, P0977 (Shift solenoid "B" (S2) circuit) P0985, P0986 (Shift solenoid "E" (SR) circuit) P0748 (Pressure control solenoid "A" (SL1) circuit) P0778 (Pressure control solenoid "B" (SL2) circuit) P2716 (Pressure control solenoid "D" (SLT) circuit) P0128 (ECT (Engine Coolant Temperature) sensor circuit) P0327, P0328, P0332, P0333 (Knock sensor circuit) |
| ETCS (Electronic Throttle Control System) | Not system down |
| Transmission shift position | "D" |
| ECT | 40°C (104°F) or more |
| Spark advance from max. retard timing by knock sensor control | 0° CA or more |
| Engine | Starting |
| Transfer range | High |
| ATF temperature | 10°C (50°F) or more |
| Summation of C1 clutch heat generations | Specified value |
| Shift solenoid valve S1 ON malfunction | Detected |
| Shift solenoid valve S2 ON malfunction | Detected |
| Shift solenoid valve SR OFF malfunction | Detected |
| 1-2 shift valve malfunction | Detected |
| Shift solenoid valve SL1 OFF malfunction | Detected |
| Shift solenoid valve SL2 ON malfunction | Detected |
| 1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P2714) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs using the Techstream.
| Result | Proceed to |
| Only P2714 is output | A |
| P2714 and other DTCs are output | B |
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING TECHSTREAM (ACTIVE THE SOLENOID (SLT)) |
![]() |
Remove the test plug on the transmission case center right side and connect SST.
Connect a Techstream to the DLC3.
Start the engine and warm it up.
Measure the line pressure with SST.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Active Test.
According to the display on the Techstream, perform the Active Test.
Measure the line pressure with SST.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Active the Solenoid (SLT)* | Operate the shift solenoid SLT and raise line pressure | ON or OFF
| [Vehicle Condition]
|
|
| ||||
| OK | |
| 3.PERFORM ACTIVE TEST USING TECHSTREAM (CONTROL THE SHIFT POSITION) |
Connect the Techstream to the DLC3.
Clear the DTC (Click here).
Warm up the engine.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Active Test.
According to the display on the Techstream, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Control the Shift Position | Operate shift solenoid valve and set each shift position by yourself |
| Possible to check operation of shift solenoid valves [Vehicle Condition] 50 km/h (30 mph) or less |
Compare the ECM gear shift command and the actual gear position.
| System Condition | ECM gear shift command | Proceed to | ||||||
| 1st | 2nd | 3rd | 4th | 5th | ||||
| Actual gear position under malfunction | Shift solenoid S1 | Stuck ON | 1st | 2nd | 2nd | 1st | N*1 | A |
| Stuck OFF | 4th | 3rd | 3rd | 4th | 5th | |||
| Shift solenoid S2 | Stuck ON*2 | 2nd | 2nd | 3rd | 3rd | N*1 | B | |
| Stuck OFF*3 | 1st | 1st | 4th | 4th | 5th | |||
| Shift solenoid SL2 | Stuck ON | 1st | 2nd | 3rd | 4th | N*1 | C | |
| Stuck OFF | 1st | 2nd | 3rd | 4th | 5th | |||
| Shift solenoid SR | Stuck ON*4 | 1st | 2nd | 3rd | 4th | 5th | D | |
| Stuck OFF*5 | 1st | 2nd | 3rd | 4th | 4th | |||
| Normal | 1st | 2nd | 3rd | 4th | 5th | E | ||
|
| ||||
|
| ||||
|
| ||||
|
| ||||
| A | |
| 4.INSPECT SHIFT SOLENOID VALVE S1 |
![]() |
Remove the shift solenoid valve S1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid S1 connector - Shift solenoid S1 body | 20°C (68°F) | 11 to 15 Ω |
| *1 | Component without harness connected: (Shift Solenoid S1) |
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
|
| ||||
| OK | |
| 5.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly.
|
| ||||
| OK | |
| 6.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 7.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| *1 | Component without harness connected: (Shift Solenoid Valve SLT) |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
|
| ||||
| OK | |
| 8.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly.
|
| ||||
| OK | |
| 9.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 10.INSPECT SHIFT SOLENOID VALVE S2 |
![]() |
Remove the shift solenoid valve S2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid S2 connector - Shift solenoid S2 body | 20°C (68°F) | 11 to 15 Ω |
| *1 | Component without harness connected: (Shift Solenoid Valve S2) |
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
|
| ||||
| OK | |
| 11.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly.
|
| ||||
| OK | |
| 12.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 13.INSPECT SHIFT SOLENOID VALVE SL2 |
![]() |
Remove the shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| *1 | Component without harness connected: (Shift Solenoid Valve SL2) |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
|
| ||||
| OK | |
| 14.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly.
|
| ||||
| OK | |
| 15.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 16.INSPECT SHIFT SOLENOID VALVE SR |
![]() |
Remove the shift solenoid valve SR.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid SR connector - Shift solenoid SR body | 20°C (68°F) | 11 to 15 Ω |
| *1 | Component without harness connected: (Shift Solenoid Valve SR) |
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
|
| ||||
| OK | |
| 17.INSPECT SHIFT SOLENOID VALVE SL1 |
![]() |
Remove the shift solenoid valve SL1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| *1 | Component without harness connected: (Shift Solenoid Valve SL1) |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
|
| ||||
| OK | |
| 18.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly.
|
| ||||
| OK | |
| 19.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 20.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| *1 | Component without harness connected: (Shift Solenoid Valve SLT) |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
|
| ||||
| OK | |
| 21.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly.
|
| ||||
| OK | |
| 22.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||