Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0712    Transmission Fluid Temperature Sensor "A" Circuit Low Input

DTC    P0713    Transmission Fluid Temperature Sensor "A" Circuit High Input

for Preparation Click here


DESCRIPTION

Refer to DTC P0711 .

DTC No.
DTC Detection Conditions
Trouble Areas
P0712
No. 1 ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1-trip detection logic).
  1. Short in No. 1 ATF temperature sensor circuit
  2. Transmission wire (No. 1 ATF temperature sensor)
  3. ECM
P0713
No. 1 ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more, and either of the following conditions is met (1-trip detection logic):.
  1. Open in No. 1 ATF temperature sensor circuit
  2. Transmission wire (No. 1 ATF temperature sensor)
  3. ECM
Condition (A): 9 minutes and 10 seconds or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (- 20.875°F) or less.
Condition (B): 10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (- 20.875°F).

MONITOR DESCRIPTION

These DTCs indicate an open or short in the Automatic Transmission Fluid (ATF) temperature sensor circuit.
The No. 1 ATF temperature sensor converts ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and detects any open or short malfunctions in the No. 1 ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or its wiring. The ECM turns on the MIL and stores a DTC.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:
The ATF temperature can be checked on a Techstream display.


MONITOR STRATEGY


Related DTCs
P0712: ATF temperature sensor/Range check (Low voltage)
P0713: ATF temperature sensor/Range check (High voltage)
Required sensors/Components
ATF temperature sensor
Frequency of operation
Continuous
Duration
0.5 seconds
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


P0712: Range check (Low voltage) 
The monitor will run whenever the following DTCs are not present.
None
The typical enabling condition is not available.
-

P0713: Range check (High voltage) 
One of the following conditions is met: Condition (A) or (B)

Condition (A) 
The monitor will run whenever the following DTCs are not present
P0115, P0117, P0118 (ECT sensor circuit)
P0110, P0112, P0113 (IAT sensor circuit)
Engine coolant temperature or intake air temperature at engine start
-29.375°C (-20.875°F) or less
Time after engine start
9 minutes and 10 seconds or more
ECT sensor circuit fail (P0115, P0117, P0118)
Not detected
IAT sensor circuit fail (P0097, P0098, P0110, P0112, P0113)
Not detected

Condition (B) 
The monitor will run whenever the following DTCs are not present
P0115, P0117, P0118 (ECT sensor circuit)
P0110, P0112, P0113 (IAT sensor circuit)
Engine coolant temperature or intake air temperature at engine start
More than -29.375°C (-20.875°F)
Time after engine start
10 seconds or more
ECT sensor circuit fail (P0115, P0117, P0118)
Not detected
IAT sensor circuit fail (P0097, P0098, P0110, P0112, P0113)
Not detected

TYPICAL MALFUNCTION THRESHOLDS


P0712: Range check (Low voltage) 
No. 1 ATF temperature sensor voltage
(No. 1 ATF temperature sensor output temperature)
Less than 0.14 V
(Higher than 164°C (327.2°F))

P0713: Range check (High voltage) 
No. 1 ATF temperature sensor voltage
(No. 1 ATF temperature sensor output temperature)
More than 4.91 V
(Less than -48°C (-54.4°F))

COMPONENT OPERATING RANGE


No. 1 ATF temperature sensor voltage
(No. 1 ATF temperature sensor output temperature)
0.14 to 4.91 V
(-48 to 164°C (-54.4 to 327.2°F))

WIRING DIAGRAM

Refer to DTC P0711 .

INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

HINT:
According to the Data List displayed on a Techstream, you can read the values of components, such as the switches, sensors and actuators, without removing any parts. Reading the Data List as a first step of troubleshooting is one method of shortening labor time.

NOTICE:
In the table below, the values listed under "Normal Condition" are for reference only. Do not depend solely on these reference values when judging whether a part is faulty or not.

  1. Warm up the engine.
  2. Turn the ignition switch to OFF.
  3. Connect the Techstream to the DLC3.
  4. Turn the ignition switch to ON.
  5. Turn the Techstream on.
  6. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data.
  7. According to the display on the Techstream, read the Data List.

Engine and ECT 
Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
A/T Oil Temperature 1
No. 1 ATF Temperature Sensor Value/
Min.: -40°C (-40°F)
Max.: 215°C (419°F)
  1. After Stall Test:
    Approximately 80°C (176°F)
  2. Equal to ambient temperature during cold soak
If the value is "-40°C (-40°F)" or "150°C (302°F) or more", No. 1 ATF temperature sensor circuit is open or short.

HINT:
When DTC P0712 is output and Techstream reading is 150°C (302°F) or more, there is a short circuit.
When DTC P0713 is output and Techstream reading is -40°C (-40°F), there is an open circuit.
Measure the resistance between terminal THO1 and the body ground.


Temperature Displayed
Malfunction
-40°C (-40°F)
Open circuit
150°C (302°F) or more
Short circuit

HINT:
If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately set (in 0.5 seconds). When P0713 is set, P0711 cannot be detected.
It is not necessary to inspect the circuit when P0711 is set.

1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)


    C213109E01
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (OT-) - 10 (OT+)
    Always
    79 Ω to 156 kΩ
    2 (OT-) - Body ground
    Always
    10 kΩ or higher
    10 (OT+) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Component without harness connected:
    (Transmission wire)

HINT:
If the resistance is outside the specified range at either of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.

ATF Temperature
Specified Condition
10°C (50°F)
5 to 8 kΩ
25°C (77°F)
2.5 to 4.5 kΩ
110°C (230°F)
0.22 to 0.28 kΩ


NG
REPAIR OR REPLACE TRANSMISSION WIRE (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C213116E01
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B49-5 (THO1) - B48-8 (ETHW)
    Always
    79 Ω to 156 kΩ
    B49-5 (THO1) - Body ground
    Always
    10 kΩ or higher
    B48-8 (ETHW) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Rear view of wire harness connector:
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)