Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0973    Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)

DTC    P0974    Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operations of the shift solenoid valves S1, S2, SR, SL1 and SL2, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be driven smoothly (Click here).

DTC No.
DTC Detection Conditions
Trouble Areas
P0973
ECM detects short in solenoid valve S1 circuit 2 times when solenoid valve S1 is operated (1-trip detection logic).
  1. Short in shift solenoid valve S1 circuit
  2. Shift solenoid valve S1
  3. ECM
P0974
ECM detects open in solenoid valve S1 circuit 2 times when solenoid valve S1 is not operated (1-trip detection logic).
  1. Open in shift solenoid valve S1 circuit
  2. Shift solenoid valve S1
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S1 circuit. When there is an open or short circuit in any shift solenoid valve circuits, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve S1 is ON, if the resistance is 8 Ω or less, the ECM determines that there is a short malfunction in the shift solenoid valve S1 circuit.
When the shift solenoid valve S1 is OFF, if the resistance is 100 kΩ or more, the ECM determines that the shift solenoid valve S1 circuit is open (Click here).

MONITOR STRATEGY


Related DTCs
P0973: Shift solenoid valve S1/Range check (Low resistance)
P0974: Shift solenoid valve S1/Range check (High resistance)
Required sensors/Components
Shift solenoid valve S1
Frequency of operation
Continuous
Duration
0.128 seconds or more
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


P0973: Range check 
The monitor will run whenever the following DTCs are not present.
None
Command to solenoid
ON

P0974: Range check 
The monitor will run whenever the following DTCs are not present.
None
Command to solenoid
OFF

TYPICAL MALFUNCTION THRESHOLDS


P0973: Range check 
Shift solenoid valve S1 resistance
8 Ω or less

P0974: Range check 
Shift solenoid valve S1 resistance
100 kΩ or more

COMPONENT OPERATING RANGE


Shift solenoid valve S1 resistance
11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM


C186141E09


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).


HINT:
The shift solenoid valve S1 is turned on/off normally when the shift lever is in the D position:

Gearshift controlled by ECM
1st
2nd
3rd
4th
5th
Shift solenoid valve S1
ON
ON
OFF
OFF
OFF

1.INSPECT TRANSMISSION WIRE (S1)


    C213109E04
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    8 (S1) - Body ground
    20°C (68°F)
    11 to 15 Ω

    Text in Illustration 
    *1
    Component without harness connected:
    (Transmission Wire)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C213114E01
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B48-36 (S1) - Body ground
    20°C (68°F)
    11 to 15 Ω

    Text in Illustration 
    *1
    Rear view of wire harness connector:
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE S1


    A110986E12
  1. Remove the shift solenoid valve S1.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid S1 connector - Shift solenoid S1 body
    20°C (68°F)
    11 to 15 Ω

    Text in Illustration 
    *1
    Component without harness connected:
    (Shift Solenoid Valve S1)

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes operating sounds.



NG
REPLACE SHIFT SOLENOID VALVE S1
OK