Home › TRANSMISSION · A750F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2757    Torque Converter Clutch Pressure Control Solenoid Performance (Shift Solenoid Valve SLU)

for Preparation Click here


DESCRIPTION

The ECM uses the signals from the throttle position sensor, air-flow meter, turbine (input) speed sensor, output speed sensor and crankshaft position sensor to monitor the engagement condition of the lock-up clutch.

C221407E03

Then the ECM compares the engagement condition of the lock-up clutch with the lock-up schedule in the ECM memory to detect mechanical problems of the shift solenoid valve SLU, valve body and torque converter.

DTC No.
DTC Detection Conditions
Trouble Areas
P2757
Lock-up does not occur when driving in the lock-up range (normal driving at 80 km/h [50 mph]), or lock-up remains ON in the lock-up OFF range (2-trip detection logic).
  1. Shift solenoid valve SLU remains open or closed
  2. Valve body is blocked
  3. Shift solenoid valve SLU
  4. Torque converter assembly
  5. Automatic transmission (clutch, brake or gear, etc.)
  6. Line pressure is too low

MONITOR DESCRIPTION

Torque converter lock-up is controlled by the ECM based on turbine (input) speed sensor NT, output speed sensor SP2, the engine rpm, engine load, engine coolant temperature, vehicle speed, transmission fluid temperature, and gear selection. The ECM determines the lock-up status of the torque converter by comparing the engine rpm (NE) with the input turbine rpm (NT). The ECM calculates the actual transmission gear by comparing the input turbine rpm (NT) with the output shaft rpm (SP2). When the conditions are appropriate, the ECM requests "lock-up" by applying the control voltage to the shift solenoid SLU. When the SLU is turned on, solenoid SLU applies pressure to the lock-up relay valve and locks the torque converter.
If the ECM detects no lock-up after lock-up has been requested or if it detects lock-up when it is not requested, the ECM interprets this as a fault in the shift solenoid valve SLU or lock-up system performance. The ECM turns on the MIL and stores the DTC.
Example:
When either of the following is met, the ECM interprets it as a malfunction.
  1. There is a difference in rotation between the input side (engine speed) and output side (input turbine speed) of the torque converter even when the ECM requests lock-up.
    (Engine speed is at least 70 rpm greater than the input turbine speed.)
  2. There is no difference in rotation between the input side (engine speed) and output side (input turbine speed) of the torque converter even when the ECM requests lock-up off.
    (The difference between the engine speed and input turbine speed is less than 35 rpm.)

MONITOR STRATEGY


Related DTCs
P2757:
Shift solenoid valve SLU/OFF malfunction
Shift solenoid valve SLU/ON malfunction
Required sensors/Components (Main)
Shift solenoid valve SLU
Required sensors/Components (Related)
Valve body, Vehicle speed sensor, Throttle position sensor, Speed sensor (NT), Speed sensor (SP2)
Frequency of operation
Continuous
Duration
OFF malfunction (A):
2 seconds
OFF malfunction (B):
0.4 seconds
ON malfunction:
1.8 seconds
MIL operation
2 driving cycles
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
The monitor will run whenever the following DTCs are not present
P0717 (Turbine speed sensor (NT) circuit)
P0722 (Output speed sensor (SP2) circuit)
P0751, P0973, P0974 (Shift solenoid "A" (S1) circuit)
P0756, P0976, P0977 (Shift solenoid "B" (S2) circuit)
P0985, P0986 (Shift solenoid "E" (SR) circuit)
P2759 (Torque converter pressure control solenoid circuit)
P0327, P0328, P0332, P0333 (Knock sensor circuit)
P0776 (Pressure control solenoid "B" (SL2) circuit)
P0781 (1-2 shift valve)
ETCS (Electronic Throttle Control System)
Not system down
Transmission shift position
"D"
Duration time from shifting "N" to "D"
4 seconds or more
ECT (Engine Coolant Temperature)
40°C (104°F) or more
Spark advance from max. retard timing by knock sensor control
0° CA or more
Engine
Starting
ECM selected gear
2nd, 3rd, 4th or 5th
Vehicle speed
25 km/h (15.5 mph) or more
Transfer neutral position switch
OFF
Transfer range
High

OFF malfunction (A) 
ECM lock-up command
ON
(SLU pressure: 513 kPa or more)
Vehicle speed
Less than 120 km/h (74.6 mph)

OFF malfunction (B) 
ECM selected gear
2nd
Vehicle speed
2 km/h (1.2 mph) or more
Output speed
2nd → 1st down shift point or more
Throttle valve opening angle
6.5% or more at engine speed of 2000 rpm
(Conditions vary with engine speed)

ON malfunction 
ECM lock-up command
OFF
(SLU pressure: less than 4 kPa)
Throttle valve opening angle
7% or more
Vehicle speed
4th gear: Less than 120 km/h (74.6 mph)
(Conditions vary with gear position)

TYPICAL MALFUNCTION THRESHOLDS

Both of the following conditions are met: OFF malfunction (A) and (B)

OFF malfunction (A) 
Engine speed - Turbine speed
70 rpm or more

OFF malfunction (B) 
Turbine speed/Output speed
Less than 3.30, or more than 7.50
[ON malfunction]
2 detections are necessary in 1 driving cycle.
1st detection; temporary flag ON
2nd detection; pending fault code ON
Vehicle speed must be under 10 km/h (6.2 mph) once before the 2nd detection.

ON malfunction 
Difference between engine speed and turbine speed
Less than 35 rpm

INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

HINT:
Performing the Active Test using a Techstream allows components, such as the relay, VSV, and actuator, to be operated without removing any parts. Performing the Active Test as a first step of troubleshooting is one method of shortening labor time.
It is possible to display the Data List during the Active Test.
  1. Warm up the engine.
  2. Turn the ignition switch off.
  3. Connect the Techstream to the DLC3.
  4. Turn the ignition switch to ON.
  5. Turn the Techstream on.
  6. Enter the following menus: Powertrain / Engine and ECT / Active Test.
  7. According to the display on the Techstream, perform the Active Test.

    Engine and ECT 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Active the Lock Up
    Control shift solenoid SLU to set automatic transmission to lock-up condition
    OFF or ON
    Possible to check shift solenoid valve SLU operation
    [Vehicle Condition]
    1. Throttle valve opening angle: Less than 35%
    2. Vehicle speed: 60 km/h (36 mph) or more

    HINT:
    This test can be conducted when the vehicle speed is 60 km/h (36 mph) or more.

  8. Lightly depress the accelerator pedal and check that the engine speed does not change abruptly.

HINT:
  1. When changing the accelerator pedal opening angle while driving, if the engine speed does not change, lock-up is on.

  2. Slowly release, but not fully, the accelerator pedal in order to decelerate. (Fully releasing the pedal causes closure of the throttle valve and lock-up may be turned off automatically.)


    C124514E01

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P2757)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Read the DTCs using the Techstream.
    Result 
    Result
    Proceed to
    Only DTC P2757 is output
    A
    P2757 and other DTCs are output
    B

    HINT:
    If any codes besides P2757 are output, perform troubleshooting for those DTCs first.



B
GO TO DTC CHART (Click here)
A


2.INSPECT SHIFT SOLENOID VALVE SLU


    C204845E01
  1. Remove the shift solenoid valve SLU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    Text in Illustration 
    *1
    Component without harness connected:
    (Shift Solenoid Valve SLU)

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes operating sounds.



NG
REPLACE SHIFT SOLENOID VALVE SLU
OK


3.INSPECT TRANSMISSION VALVE BODY ASSEMBLY
  1. Check the transmission valve body assembly.

    HINT:
    Refer to Problem Symptoms Table Chapter 2 (Click here).

OK:
There are no foreign objects on any valves and they operate smoothly.



NG
REPAIR OR REPLACE TRANSMISSION VALVE BODY ASSEMBLY (Click here)
OK


4.INSPECT TORQUE CONVERTER ASSEMBLY
  1. Check the torque converter assembly (Click here).

    OK:
    The torque converter operates normally.



NG
REPLACE TORQUE CONVERTER ASSEMBLY
OK

REPAIR OR REPLACE AUTOMATIC TRANSMISSION ASSEMBLY (Click here)