DTC P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2) |
| DTC No. | DTC Detection Conditions | Trouble Areas |
| P0778 | The ECM checks for an open or short in the shift solenoid valve SL2 circuit (1-trip detection logic):
|
|
| Related DTCs | P0778: Shift solenoid valve SL2/Range check |
| Required sensors/Components | Shift solenoid valve SL2 |
| Frequency of operation | Continuous |
| Duration | 1 second |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present. | None |
| Ignition switch | ON |
| Starter | OFF |
| Solenoid current cut status | Not cut |
| Battery voltage | 11 V or more |
| Target duty cycle | 19% or more |
| Solenoid status from solenoid driver MIC | Fail |
| Output signal duty | Less than 100% |

| Gearshift controlled by ECM | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve SL2 | ON | ON | ON | ON | OFF |
| 1.INSPECT TRANSMISSION WIRE (SL2) |
![]() |
Disconnect the B37 transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 11 (SL2+) - 3 (SL2-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 11 (SL2+) - Body ground | Always | 10 kΩ or higher |
| 3 (SL2-) - Body ground | Always | 10 kΩ or higher |
| *1 | Component without harness connected: (Transmission Wire) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the B37 transmission wire connector to the transmission.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B48-31 (SL2+) - B49-34 (SL2-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| B48-31 (SL2+) - Body ground | Always | 10 kΩ or higher |
| B49-34 (SL2-) - Body ground | Always | 10 kΩ or higher |
| *1 | Rear view of wire harness connector: (to ECM) |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SL2 |
![]() |
Remove the shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| *1 | Component without harness connected: (Shift Solenoid Valve SL2) |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
|
| ||||
| OK | ||
| ||