DTC P0571 Stop Light Switch Circuit Malfunction |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0571 | The voltages of terminals ST1- and STP of the ECM are both below 1 V for 0.5 seconds or more. |
|

| 1.CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH ASSEMBLY - BATTERY) |
![]() |
Disconnect the A3 stop light switch assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A3-2 - Body ground | Always | 11 to 14 V |
| A3-4 - Body ground | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Stop Light Switch Assembly) |
|
| ||||
| OK | |
| 2.INSPECT STOP LIGHT SWITCH ASSEMBLY |
![]() |
Remove the stop light switch (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 - 2 | Not pushed | Below 1 Ω |
| Pushed | 10 kΩ or higher | |
| 3 - 4 | Not pushed | 10 kΩ or higher |
| Pushed | Below 1 Ω |
| *a | Component without harness connected (Stop Light Switch Assembly) |
| *b | Not Pushed |
| *c | Pushed |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (ECM - STOP LIGHT SWITCH ASSEMBLY) |
Disconnect the A3 stop light switch assembly connector.
Disconnect the E77 and E78 ECM connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E78-8 (ST1-) - A3-3 | Always | Below 1 Ω |
| E77-18 (STP) - A3-1 | Always | Below 1 Ω |
| E78-8 (ST1-) - Body ground | Always | 10 kΩ or higher |
| E77-18 (STP) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||