Home › BRAKE › BRAKE CONTROL › VEHICLE STABILITY CONTROL SYSTEM

VEHICLE STABILITY CONTROL SYSTEM > AUTO LSD Indicator Light does not Come ON

for Preparation Click here


DESCRIPTION

The AUTO LSD does not operate even if the VSC OFF switch is pressed under the following conditions:
  1. The brake system is faulty.
  2. The temperature inside the hydraulic brake booster increases and the AUTO LSD operation is suspended.

WIRING DIAGRAM

Refer to AUTO LSD Indicator Light Remains ON .

INSPECTION PROCEDURE

NOTICE:
When replacing the master cylinder solenoid, perform calibration (Click here).

1.CHECK CAN COMMUNICATION LINE
  1. Turn the ignition switch off.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Select CAN Bus Check from the System Selection Menu screen and follow the prompts on the screen to inspect the CAN bus (Click here).

    OK:
    CAN Bus Check indicates no malfunctions in CAN communication.



NG
GO TO CAN COMMUNICATION SYSTEM (HOW TO PROCEED WITH TROUBLESHOOTING) (Click here)
OK


2.INSPECT VSC OFF SWITCH
  1. Remove the VSC OFF switch (Click here).



    C234071E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    3 - 4
    Switch is not pushed
    10 kΩ or higher
    Switch is pushed
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (VSC OFF Switch)



NG
REPLACE VSC OFF SWITCH (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - VSC OFF SWITCH)
  1. Disconnect the A4 skid control ECU connector.

  1. Disconnect the E3 VSC OFF switch connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A4-9 (CSW) - E3-3
    Always
    Below 1 Ω
    A4-9 (CSW) - Body ground
    Always
    10 kΩ or higher
    E3-4 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Turn the ignition switch off.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Combination Meter / Active Test.

  1. According to the display on the Techstream, perform the Active Test.

    Combination Meter  
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Indicat. Auto LSD
    Auto LSD indicator light
    OFF/ON
    Perform the test with the vehicle stopped and the engine idling.

OK:
The Auto LSD indicator light turns ON or OFF according to the Techstream operations.



NG
Go to step 5
OK

REPLACE MASTER CYLINDER SOLENOID (Click here)  

5.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Turn the ignition switch off.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Chassis / ABS/VSC/TRAC / Active Test.

  1. According to the display on the Techstream, perform the Active Test.

    ABS/VSC/TRAC 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Auto LSD Indicator Light
    Auto LSD indicator light
    Indicator light OFF/ON
    Observe the combination meter.

  1. Using the Techstream, check that the Data List display changes from OFF to ON.

    ABS/VSC/TRAC 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Auto LSD Indicator Light
    Auto LSD indicator light/ ON or OFF
    ON: Indicator light on
    OFF: Indicator light off
    -

    OK:
    Data List display changes from OFF to ON



NG
REPLACE MASTER CYLINDER SOLENOID (Click here)
OK

GO TO METER / GAUGE SYSTEM (HOW TO PROCEED WITH TROUBLESHOOTING) (Click here)