Home › ENGINE › 1GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0416    Secondary Air Injection System Switching Valve "B" Circuit Open

DTC    P0417    Secondary Air Injection System Switching Valve "B" Circuit Shorted

for Preparation Click here


DESCRIPTION

The ECM operates the air injection VSV relay (AI-VSV) which causes the No. 2 emission control valve set to operate.

DTC No.
DTC Detection Condition
Trouble Area
P0416
Open or short in the air injection VSV relay (AI-VSV) circuit for 3 seconds (1 trip detection logic).
  1. Open or short in air injection VSV relay (AI-VSV) circuit
  2. Air injection VSV relay (AI-VSV)
  3. ECM
P0417
Open or short in the air injection VSV relay (AI-VSV) circuit for 3 seconds (1 trip detection logic).
  1. Open or short in air injection VSV relay (AI-VSV) circuit
  2. Air injection VSV relay (AI-VSV)
  3. ECM

MONITOR DESCRIPTION

These DTCs are designed to detect a malfunction in the air injection VSV relay (AI-VSV) circuit. When the system is normal, the battery voltage is applied to terminal AIR1 of the ECM while the air injection VSV relay (AI-VSV) is turned off, and the battery voltage is not applied to terminal AIR1 of the ECM while the air injection VSV relay (AI-VSV) is turned on. The ECM illuminates the MIL and stores a DTC when either one of the following conditions is detected.
  1. The battery voltage is not applied to terminal AIR1 while the air injection VSV relay (AI-VSV) is off.
  2. The battery voltage is applied to terminal AIR1 while the air injection VSV relay (AI-VSV) is on.

MONITOR STRATEGY


Related DTCs
P0416: Secondary air injection system air switching valve circuit range check low voltage (Bank 2)
P0417: Secondary air injection system air switching valve circuit range check high voltage (Bank 2)
Required Sensors/Components
Air injection VSV relay (AI-VSV)
Required Sensors/Components
ECM
Frequency of Operation
Continuous
Duration
3 seconds
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Case 1 
Monitor runs whenever following DTCs not stored
None
Current command to air injection VSV relay (AI-VSV)
ON
Last command to air injection VSV relay (AI-VSV)
ON
Battery voltage
8 V or higher
Ignition switch
ON
Starter
OFF

Case 2 
Monitor runs whenever following DTCs not stored
None
Current command to air injection VSV relay (AI-VSV)
OFF
Last command to air injection VSV relay (AI-VSV)
OFF
Battery voltage
8 V or higher
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS


P0416 
Air injection VSV relay (AI-VSV) output terminal voltage level
Low

P0417 
Air injection VSV relay (AI-VSV) output terminal voltage level
High

CONFIRMATION DRIVING PATTERN

NOTICE:
  1. This Secondary Air Injection Check only allows technicians to operate the secondary air injection system for a maximum of 5 seconds. Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks. While secondary air injection system operation using the Techstream is prohibited, the Techstream display indicates the prohibition (WAIT or ERROR). If ERROR is displayed on the Techstream during the test, stop the engine for 10 minutes, and then try again.
  2. Performing Secondary Air Injection Check repeatedly may cause damage to the secondary air injection system. If it is necessary to repeat the check, leave an interval of several minutes between System Check operations to prevent the system from overheating.
  3. When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
  4. Turn the ignition switch off when the Secondary Air Injection Check operation finishes.

  1. Start the engine and warm it up.
  2. Turn the ignition switch off.
  3. Connect the Techstream to the DLC3.
  4. Turn the ignition switch to ON.
  5. Turn the Techstream on.
  6. Clear the DTCs (even if no DTCs are stored, perform the clear DTC operation).
  7. Turn the ignition switch off and wait for at least 30 seconds.
  8. Turn the ignition switch to ON and turn the Techstream on.
  9. Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air injection check / Automatic Mode.
  10. Start the engine after the Techstream initialization is finished.
  11. Perform the System Check operation by pressing Next.
  12. Perform the following to confirm the secondary air injection system pending DTCs: Press the Exit.
  13. Enter the following menus: Powertrain / Engine and ECT / Trouble codes.
  14. Read pending DTCs.

    HINT:
    1. If a pending DTC is output, the system is malfunctioning.
    2. If a pending DTC is not output, perform the following procedure.

  15. After Secondary Air Injection Check is completed, check All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  16. Input the DTC: P0416 or P0417.
  17. Check the DTC judgment result.

    Techstream Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    HINT:
    1. If the judgment result shows NORMAL, the system is normal.
    2. If the judgment result shows ABNORMAL, the system has a malfunction.

  18. If the judgment result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (Click here).

    HINT:
    1. If no permanent DTC is output, the system is normal.
    2. If a permanent DTC is output, the system is malfunctioning.

  19. Turn the ignition switch off.

WIRING DIAGRAM


A240036E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

HINT:
  1. By using the Techstream to perform the Secondary Air Injection Check operation in the System Check, the air-fuel ratio and the pressure in the secondary air injection system passage can be checked while the secondary air injection system is operating. This helps technicians to troubleshoot the system when it malfunctions.
  2. Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
  3. Bank 1 refers to the bank that includes the No. 1 cylinder*.
    *: The No. 1 cylinder is the cylinder which is farthest from the transmission.
  4. Bank 2 refers to the bank that does not include the No. 1 cylinder.

1.INSPECT AIR INJECTION VSV RELAY (AI-VSV)
A232574E01
  1. Remove the air injection VSV relay (AI-VSV) from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied
    10 kΩ or higher
    Battery voltage applied to terminals 1 and 2
    Below 1 Ω



NG
REPLACE AIR INJECTION VSV RELAY (AI-VSV)
OK


2.CHECK AIR INJECTION VSV RELAY (AI-VSV) (POWER SOURCE)
  1. Remove the air injection VSV relay (AI-VSV) from the engine room relay block.



    A287417E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    1 (Air injection VSV relay (AI-VSV)) - Body ground
    Ignition switch ON
    11 to 14 V
    5 (Air injection VSV relay (AI-VSV)) - Body ground
    Always
    11 to 14 V

    Text in Illustration 
    *1
    Engine Room Relay Block
    *2
    Air Injection VSV Relay (AI-VSV)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (ECM - AIR INJECTION VSV RELAY (AI-VSV))
  1. Remove the air injection VSV relay (AI-VSV) from the engine room relay block.

  1. Disconnect the B49 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    2 (Air injection VSV relay (AI-VSV)) - B49-21 (AIR1)
    Always
    Below 1 Ω
    2 (Air injection VSV relay (AI-VSV)) or B49-21 (AIR1) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)