Home › ENGINE · 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM (w/ Secondary Air Injection System)

DTC    P0136    Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2)

DTC    P0137    Heated Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2)

DTC    P0138    Heated Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2)

for Preparation Click here


DESCRIPTION

HINT:
Sensor 2 refers to the sensor mounted behind the Three-Way Catalytic Converter (TWC) and located far from the engine assembly.

In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a TWC is used. For the most efficient use of the TWC, the air-fuel ratio must be precisely controlled so that it is always close to the stoichiometric air-fuel level. For the purpose of helping the ECM to deliver accurate air-fuel ratio control, a Heated Oxygen (HO2) sensor is used.
The HO2 sensor is located behind the TWC, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The HO2 sensor informs the ECM that the post-TWC air-fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air-fuel ratio is richer than the stoichiometric air-fuel level, the oxygen concentration in the exhaust gas becomes lean. The HO2 sensor informs the ECM that the post-TWC air-fuel ratio is rich (high voltage, i.e. more than 0.45 V). The HO2 sensor has the property of changing its output voltage drastically when the air-fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the HO2 sensor to determine whether the air-fuel ratio after the TWC is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the HO2 sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air-fuel ratio control.

A088111E01


DTC No.
DTC Detection Conditions
Trouble Areas
P0136
  1. Abnormal voltage output:
    During active air-fuel ratio control, following conditions (a) and (b) are met for certain period of time (2 trip detection logic):
    1. Heated Oxygen (HO2) sensor voltage does not decrease to less than 0.2 V
    2. HO2 sensor voltage does not increase to more than 0.6 V
  2. Low impedance:
    Sensor impedance less than 5 Ω for more than 30 seconds when ECM presumes sensor to being warmed up and operating normally (1 trip detection logic)
  1. Open or short in HO2 sensor (sensor 2) circuit
  2. HO2 sensor (sensor 2)
  3. HO2 sensor heater (sensor 2)
  4. Air-Fuel Ratio (A/F) sensor (sensor 1)
  5. Integration relay (MAIN relay)
  6. Gas leakage from exhaust system
P0137
  1. Low voltage (open):
    During active air-fuel ratio control, following conditions (a) and (b) are met for certain period of time (2 trip detection logic):
    1. HO2 sensor voltage output less than 0.21 V
    2. Target air-fuel ratio rich
  2. High impedance:
    Sensor impedance 15 kΩ or more for more than 90 seconds when ECM presumes sensor to being warmed up and operating normally (1 trip detection logic)
  1. Open in HO2 sensor (sensor 2) circuit
  2. HO2 sensor (sensor 2)
  3. HO2 sensor heater (sensor 2)
  4. Integration relay (MAIN relay)
  5. Gas leakage from exhaust system
P0138
  1. High voltage (short):
    During active air-fuel ratio control, following conditions (a) and (b) are met for certain period of time (2 trip detection logic):
    1. HO2 sensor voltage output 0.59 V or more
    2. Target air-fuel ratio lean
  2. Extremely high voltage (short):
    HO2 sensor voltage output exceeds 1.2 V for more than 30 seconds (1 trip detection logic)
  1. Short in HO2 sensor (sensor 2) circuit
  2. HO2 sensor (sensor 2)
  3. ECM internal circuit malfunction

MONITOR DESCRIPTION

  1. Active Air-Fuel Ratio Control
    The ECM usually performs air-fuel ratio feedback control so that the Air-Fuel Ratio (A/F) sensor output indicates a near stoichiometric air-fuel level. This vehicle includes active air-fuel ratio control in addition to regular air-fuel ratio control. The ECM performs active air-fuel ratio control to detect any deterioration in the Three-Way Catalytic Converter (TWC) and Heated Oxygen (HO2) sensor malfunctions (refer to the diagram below).
    Active air-fuel ratio control is performed for approximately 15 to 20 seconds while driving with a warm engine.
    During active air-fuel ratio control, the air-fuel ratio is forcibly regulated to become lean or rich by the ECM.
    If the ECM detects a malfunction, one of the following DTCs is set: DTC P0136 (abnormal voltage output), P0137 (open circuit) and P0138 (short circuit).
  1. Abnormal Voltage Output of HO2 Sensor (DTCs P0136)
    While the ECM is performing active air-fuel ratio control, the air-fuel ratio is forcibly regulated to become rich or lean. If the sensor is not functioning properly, the voltage output variation is small. For example, when the HO2 sensor voltage does not decrease to less than 0.21 V and does not increase to more than 0.59 V during active air-fuel ratio control, the ECM determines that the sensor voltage output is abnormal and sets DTC P0136.

    A076837E01

  1. Open or Short in Heated Oxygen (HO2) Sensor Circuit (DTCs P0137 or P0138)
    During active air-fuel ratio control, the ECM calculates the Oxygen Storage Capacity (OSC)* of the Three-Way Catalytic Converter (TWC) by forcibly regulating the air-fuel ratio to become rich or lean.
    If the HO2 sensor has an open or short, or the voltage output of the sensor noticeably decreases, the OSC indicates an extraordinarily high value. Even if the ECM attempts to continue regulating the air-fuel ratio to become rich or lean, the HO2 sensor output does not change.
    While performing active air-fuel ratio control, when the target air-fuel ratio is rich and the HO2 sensor voltage output is 0.21 V or less (lean), the ECM interprets this as an abnormally low sensor output voltage and sets DTC P0137. When the target air-fuel ratio is lean and the voltage output is 0.59 V or more (rich) during active air-fuel ratio control, the ECM determines that the sensor voltage output is abnormally high, and sets DTC P0138.

    HINT:
    DTC P0138 is also set if the HO2 sensor voltage output is more than 1.2 V for 30 seconds or more.

    *: The TWC has the capability to store oxygen. The OSC and the emission purification capacity of the TWC are mutually related. The ECM determines whether the catalyst has deteriorated, based on the calculated OSC value .

    A080024E01

  1. High or Low Impedance of Heated Oxygen (HO2) Sensor (DTC P0136 or P0137)
    During normal air-fuel ratio feedback control, there are small variations in the exhaust gas oxygen concentration. In order to continuously monitor the slight variation of the HO2 sensor signal while the engine is running, the impedance* of the sensor is measured by the ECM. The ECM determines that there is a malfunction in the sensor when the measured impedance deviates from the standard range.
    *: The effective resistance in an alternating current electrical circuit.
    A110001E01

    HINT:
    1. The impedance cannot be measured using an ohmmeter.
    2. DTC P0136 indicates the deterioration of the HO2 sensor. The ECM sets the DTCs by calculating the impedance of the sensor when the typical enabling conditions are satisfied (1 driving cycle).
    3. DTC P0137 indicates an open or short circuit in the HO2 sensor (1 driving cycle). The ECM sets the DTCs when the impedance of the sensor exceeds the threshold 15 kΩ.


WIRING DIAGRAM


A111659E01


CONFIRMATION DRIVING PATTERN

HINT:
Performing this confirmation pattern will activate the DTC detection (P0136) of the ECM. This is very useful for verifying the completion of a repair.


A092806E01

  1. Clear the DTCs (Click here).
  2. Activate the check mode (Click here).
  3. Start the engine and warm it up with all the accessory switches OFF.
  4. Deactivate the check mode and drive the vehicle at 70 to 88 km/h (44 to 55 mph) for 5 to 10 minutes.
  5. Read DTCs.

NOTICE:
  1. If the conditions in this test are not strictly followed, no malfunction will be detected.
  2. Do not drive the vehicle with check mode activated, otherwise the transaxle may be damaged.


INSPECTION PROCEDURE

HINT:
When using an intelligent tester only:
Malfunctioning areas can be identified by performing the A/F Control function provided in the Active Test. The A/F Control function can help to determine whether the Air-Fuel Ratio (A/F) sensor, Heated Oxygen (HO2) sensor and other potential trouble areas are malfunctioning.

The following instructions describe how to conduct the A/F Control operation using an intelligent tester.
  1. Connect an intelligent tester to the DLC3.
  2. Start the engine and turn the tester ON.
  3. Warm up the engine at an engine speed of 2,500 rpm for approximately 90 seconds.
  4. On the tester, select the following menu items: Powertrain / Engine and ECT / Active Test / AF Control
  5. Perform the A/F Control operation with the engine in an idling condition.
  6. Monitor the voltage outputs of the A/F and HO2 sensors (AFS B1S1 and O2S B1S2) displayed on the tester.

HINT:
  1. The A/F Control operation lowers the fuel injection volume by 12.5 % or increases the injection volume by 25 %.
  2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.


Voltage:

Tester Display
(Sensor)
Injection Volumes
Status
Voltages
AFS B1S1
(A/F)
+25 %
Rich
Less than 3.0
AFS B1S1
(A/F)
-12.5 %
Lean
More than 3.35
O2S B1S2
(HO2)
+25 %
Rich
More than 0.5
O2S B1S2
(HO2)
-12.5 %
Lean
Less than 0.4

NOTICE:
The Air-Fuel Ratio (A/F) sensor has an output delay of a few seconds and the Heated Oxygen (HO2) sensor has a maximum output delay of approximately 20 seconds.


Case
A/F Sensor (Sensor 1)
Output Voltage
HO2 Sensor (Sensor 2)
Output Voltage
Mainly Suspected Trouble Areas
1
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
-
Output voltage
More than 3.35 V
Less than 3.0 V
A104056
Output voltage
More than 0.5 V
Less than 0.4 V
A104057
2
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
  1. A/F sensor
  2. A/F sensor heater
  3. A/F sensor circuit
Output voltage
Almost no reaction
A103185
Output voltage
More than 0.5 V
Less than 0.4 V
A104057
3
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
  1. HO2 sensor
  2. HO2 sensor heater
  3. HO2 sensor circuit
Output voltage
More than 3.35 V
Less than 3.0 V
A104056
Output voltage
Almost no reaction
A103185
4
Injection volume
+25 %
-12.5 %
A103184
Injection volume
+25 %
-12.5 %
A103184
  1. Injector
  2. Fuel pressure
  3. Gas leakage from exhaust system
(Air-fuel ratio extremely lean or rich)
Output voltage
Almost no reaction
A103185
Output voltage
Almost no reaction
A103185
  1. Following the A/F Control procedure enables technicians to check and graph the voltage outputs of both the A/F and HO2 sensors.
  2. To display the graph, select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / AFS B1S1 and O2S B1S2.

HINT:
  1. If other DTCs relating to different systems that have terminal E2 as the ground terminal are output simultaneously, terminal E2 may have an open circuit.
  2. Read freeze frame data using an intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
  3. If the OX1B wire from the ECM connector is short-circuited to the +B wire, DTC P0136 will be set.

1.READ OUTPUT DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position and turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / DTC.

  1. Read DTCs.

    Result:

    Display (DTC Output)
    Proceed To
    P0138
    A
    P0137
    B
    P0136
    C



B
Go to step 14

C
Go to step 7
A


2.READ VALUE OF INTELLIGENT TESTER (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position and turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / O2S B1S2.

  1. Allow the engine to idle.

  1. Read the Heated Oxygen (HO2) sensor output voltage while idling.

    Result:

    HO2 Sensor Output Voltages
    Proceed To
    More than 1.2 V
    A
    Less than 1.0 V
    B



B
Go to step 5
A


3.CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT)


    A065743E18
  1. Turn the ignition switch to OFF and wait for 5 minutes.

  1. Disconnect the D1 ECM connector.

  1. Measure the resistance.

    Resistance:
    Tester Connections
    Specified Conditions
    HT1B (D1-2) - OX1B (D1-25)
    10 kΩ or higher

  1. Reconnect the ECM connector.



NG
Go to step 4
OK

REPLACE ECM 

4.INSPECT HEATED OXYGEN SENSOR (CHECK FOR SHORT)


    A058685E01
  1. Disconnect the D35 HO2 sensor connector.

  1. Measure the resistance.

    Resistance:
    Tester Connections
    Specified Conditions
    +B (2) - E2 (4)
    10 kΩ or higher
    +B (2) - OX1B (3)
    10 kΩ or higher

  1. Reconnect the HO2 sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

5.PERFORM CONFIRMATION DRIVING PATTERN

NEXT


6.CHECK WHETHER DTC OUTPUT RECURS (DTC P0138)
  1. On the intelligent tester, select the following menu items: Powertrain / Engine and ECT / DTC.

  1. Read DTCs.

    Result:

    Display (DTC Output)
    Proceed To
    P0138
    A
    No output
    B



B
CHECK FOR INTERMITTENT PROBLEMS
A

REPLACE HEATED OXYGEN SENSOR 

7.READ VALUE OF INTELLIGENT TESTER (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position and turn the tester ON.

  1. Start the engine.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / O2S B1S2.

  1. After warming up the engine, run the engine at an engine speed of 2,500 rpm for 3 minutes.

  1. Read the output voltage of the HO2 sensor when the engine rpm is suddenly increased.

    HINT:
    Quickly accelerate the engine to 4,000 rpm 3 times using the accelerator pedal.

    Voltage:
    Fluctuates between 0.4 V or less and 0.5 V or more.



NG
Go to step 14
OK


8.PERFORM CONFIRMATION DRIVING PATTERN

NEXT


9.CHECK WHETHER DTC OUTPUT RECURS (DTC P0136)
  1. On the intelligent tester, select the following menu items: Powertrain / Engine and ECT / DTC.

  1. Read DTCs.

    Result:

    Display (DTC Output)
    Proceed To
    P0136
    A
    No output
    B



B
CHECK FOR INTERMITTENT PROBLEMS
A


10.REPLACE HEATED OXYGEN SENSOR

NEXT


11.PERFORM CONFIRMATION DRIVING PATTERN

NEXT


12.CHECK WHETHER DTC OUTPUT RECURS (DTC P0136)
  1. On the intelligent tester, select the following menu items: Powertrain / Engine and ECT / DTC.

  1. Read DTCs.

    Result:

    Display (DTC Output)
    Proceed To
    P0136
    A
    No output
    B



B
REPAIR COMPLETED
A


13.PERFORM ACTIVE TEST BY INTELLIGENT TESTER (INJECTION VOLUME)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine and turn the tester ON.

  1. Warm up the engine.

  1. Select the following menu items: Powertrain / Engine and ECT / Active Test / Inj Vol.



  1. Change the fuel injection volume using the tester, monitoring the voltage output of Air-Fuel Ratio (A/F) and HO2 sensors displayed on the tester.

    HINT:
    1. Change the fuel injection volume within the range from -12 % to +12 %. The injection volume can be changed in 1 % graduations within the range.
    2. The A/F sensor is displayed as AFS B1S1, and the HO2 sensor is displayed as O2S B1S2 on intelligent testers.


    Result:

    Tester Display (Sensor)
    Voltage Variations
    Proceed To
    AFS B1S1 (A/F)
    Alternates between more and less than 3.3 V
    OK
    AFS B1S1 (A/F)
    Remains more than 3.3 V
    NG
    AFS B1S1 (A/F)
    Remains less than 3.3 V
    NG

    HINT:
    A normal HO2 sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the A/F sensor voltage remains either less or more than 3.3 V despite the HO2 sensor indicating a normal reaction, the A/F sensor is malfunctioning.


    A087979E03



NG
REPLACE AIR FUEL RATIO SENSOR
OK

CHECK AND REPAIR EXTREMELY RICH OR LEAN ACTUAL AIR FUEL RATIO (INJECTOR, FUEL PRESSURE, GAS LEAKAGE FROM EXHAUST SYSTEM) 

14.CHECK FOR EXHAUST GAS LEAKAGE

OK:
No gas leakage.



NG
REPAIR OR REPLACE EXHAUST GAS LEAKAGE POINT
OK


15.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)


    A058685E01
  1. Disconnect the D35 HO2 sensor connector.

  1. Measure the resistance between the terminals of the HO2 sensor connector.

    Resistance:
    Tester Connections
    Specified Conditions
    HT1B (1) - +B (2)
    11 to 16 Ω at 20°C (68°F)
    HT1B (1) - E2 (4)
    10 kΩ or higher

  1. Reconnect the HO2 sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR
OK


16.INSPECT INTEGRATION RELAY (MAIN RELAY)
  1. Remove the integration relay from the engine room R/B No.1.



    A095606E01
  1. Measure the integration relay (MAIN relay) resistance.

    Resistance:
    Tester Connections
    Specified Conditions
    A1 - B4
    10 kΩ or higher
    A1 - B4
    Below 1 Ω
    (when battery voltage applied to terminals B2 and B3)

  1. Reinstall the integration relay.



NG
REPLACE INTEGRATION RELAY
OK


17.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)


    A109987E02
  1. Disconnect the D35 HO2 sensor connector.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage between the +B terminal of the HO2 sensor connector and body ground.

    Voltage:
    Tester Connections
    Specified Conditions
    +B (D35-2) - Body ground
    9 to 14 V

  1. Turn the ignition switch to OFF.

  1. Disconnect the D1 ECM connector.

  1. Measure the resistance.

    Resistance (Check for open):
    Tester Connections
    Specified Conditions
    HT1B (D35-1) - HT1B (D1-2)
    Below 1 Ω
    OX1B (D35-3) - OX1B (D1-25)
    Below 1 Ω
    E2 (D35-4) - E2 (D1-28)
    Below 1 Ω

    Resistance (Check for short):
    Tester Connections
    Specified Conditions
    HT1B (D35-1) or HT1B (D1-2) - Body ground
    10 kΩ or higher
    OX1B (D35-3) or OX1B (D1-25) - Body ground
    10 kΩ or higher
    E2 (D35-4) or E2 (D1-28) - Body ground
    10 kΩ or higher

  1. Reconnect the HO2 sensor connector.



  1. Reconnect the ECM connectors.


    A110707E01



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HEATED OXYGEN SENSOR