CAN COMMUNICATION SYSTEM > Open in CAN Main Bus Line |
| Symptom | Trouble Area |
| Resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is more than 69 Ω. |
|

| 1.CHECK DLC3 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Value | Result |
| H23-6 (CANH) - H23-14 (CANL) | IG switch OFF | 108 to 132 Ω | A |
| H23-6 (CANH) - H23-14 (CANL) | IG switch OFF | 132 Ω or higher | B |
|
| ||||
| A | |
| 2.INSPECT CAN J/C |
![]() |
Disconnect the CAN main bus line connector (H4) from the CAN J/C.
![]() |
Measure the resistance according to the value(s) in the table below.
| Between the terminals where the connector (H4) was connected | Condition | Specified value |
| CANH - CANL | IG switch OFF | 108 to 132 Ω |
|
| ||||
| OK | |
| 3.INSPECT ECM |
![]() |
Disconnect the connector (B7) from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified value |
| B7-33 (CANH) - B7-34 (CANL) | IG switch OFF | 108 to 132 Ω |
| Tester connection | Condition | Specified value |
| B7-24 (CANH) - B7-23 (CANL) | IG switch OFF | 108 to 132 Ω |

|
| ||||
| OK | ||
| ||